HP 3PAR StoreServ 7400 4-node HP 3PAR Command Line Interface Reference (OS 3.1 - Page 629
statvv
View all HP 3PAR StoreServ 7400 4-node manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 629 highlights
statvv DESCRIPTION The statvv command displays statistics for Virtual Volumes (VVs) in a timed loop. SYNTAX statvv [options ] [...] AUTHORITY Any role in the system. OPTIONS -domain ... Shows only the VVs that are in domains with names that match the specified domain names or patterns. -rw Specifies that the display includes separate read and write data. If not specified, the total is displayed. -d Specifies the interval, in seconds, that statistics are sampled using an integer from 1 through 2147483. If no interval is specified, the option defaults to an interval of two seconds. -iter Specifies that the histogram is to stop after the indicated number of iterations using an integer from 1 through 2147483647. -sortcol [,][:[,]...] Sorts command output based on the column number (). Columns are numbered from left to right, beginning with 0. At least one column must be specified. In addition, the direction of sorting () can be specified as follows: inc Sort in increasing order (default). dec Sort in decreasing order. Multiple columns can be specified separated by a colon (:) Rows with the same information in them as earlier columns will be sorted by the values in the later columns. -filt statvv 629