HP 418800-B21 HP StorageWorks 70 Modular Smart Array Enclosure maintenance and - Page 52
Verifying component failure, Removing the backplane
UPC - 882780564640
View all HP 418800-B21 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
Verifying component failure Use the following methods to verify component failure: • Check the hard drive status LEDs as identified in the following table. Check with known good hard drives. • Check the host log for errors. Hard drive LED combinations Online/activity LED Fault/UID LED (green) (amber/blue) On, off, or flashing Alternating amber and blue On, off, or flashing Steadily blue On Amber, flashing regularly (1 Hz) On Flashing regularly (1 Hz) Off Amber, flashing regularly (1 Hz) Flashing regularly Off (1 Hz) Flashing irregularly Amber, flashing regularly (1 Hz) Flashing irregularly Off Off Steadily amber Off Amber, flashing regularly (1 Hz) Off Off Interpretation The drive has failed, or a predictive failure alert has been received for this drive; it also has been selected by a management application. The drive is operating normally, and it has been selected by a management application. A predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is online, but it is not currently active. Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is part of an array that is undergoing capacity expansion or a stripe size migration, but a predictive failure alert has been received for this drive. To minimize the risk of data loss, do not replace the drive until the expansion or migration is complete. Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is rebuilding, or it is part of an array that is undergoing capacity expansion or a stripe size migration. The drive is active, but a predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is active and it is operating normally. A critical fault condition has been identified for this drive and the controller has placed it offline. Replace the drive as soon as possible. A predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is offline, a spare, or not configured as part of an array. Removing the backplane 1. Power down the enclosure: a. Power down any attached servers. See the server documentation. b. Press the Power On/Standby button on the enclosure. c. Wait for the system power LED to go from green to amber. d. Disconnect the power cords. 2. Extend or remove the enclosure from the rack in which it may be installed: a. Loosen the front panel thumbscrews that secure the enclosure faceplate to the front of the rack. Removal and replacement procedures 52