HP AA988A HP StorageWorks 2012sa Modular Smart Array user guide (488320-002, J - Page 13

Hardware Components and LEDs, Controller Enclosure Components and LEDs

Page 13 highlights

Hardware Components and LEDs This section describes the main hardware components of your storage system enclosures. Controller Enclosure Components and LEDs Table 1-1 describes the controller enclosure components. Table 1-1 Controller Enclosure Components Description Quantity Controller (I/O) module 1 or 21 SAS or SATA drive module 2-12 per enclosure AC power-and-cooling module 2 per enclosure 3-Gbps, 4-lane SAS host ports (SFF-8088 2 per controller module standard interface) 3-Gbps, 4-lane SAS expansion port (SFF- 1 per controller module 8470 standard interface) Ethernet port (RJ-45) 1 per controller module CLI port (RS-232 micro-DB9) 1 per controller module 1 Air-management system drive blanks or I/O blanks must fill empty slots to maintain optimum airflow through the chassis. Chapter 1 System Components 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102

Chapter 1
System Components
13
Hardware Components and LEDs
This section describes the main hardware components of your storage system
enclosures.
Controller Enclosure Components and LEDs
Table 1-1 describes the controller enclosure components.
Table 1-1
Controller Enclosure Components
Description
Quantity
Controller (I/O) module
1 or 2
1
1
Air-management system drive blanks or I/O blanks must fill empty slots to maintain optimum airflow through the chassis.
SAS or SATA drive module
2–12 per enclosure
AC power-and-cooling module
2 per enclosure
3-Gbps, 4-lane SAS host ports (SFF-8088
standard interface)
2 per controller module
3-Gbps, 4-lane SAS expansion port (SFF-
8470 standard interface)
1 per controller module
Ethernet port (RJ-45)
1 per controller module
CLI port (RS-232 micro-DB9)
1 per controller module