HP AA988A HP StorageWorks 2012sa Modular Smart Array user guide (488320-002, J - Page 57
Is the controller back panel Fault/Service Required LED amber?, Are both drive module LEDs
UPC - 829160184661
View all HP AA988A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
Is the controller back panel Fault/Service Required LED amber? Answer No Yes (blinking) Yes Possible Reasons System functioning properly. One of the following errors occurred: • Hardware-controlled power- up error • Cache flush error • Cache self-refresh error An enclosure-level fault occurred. If installing a controller FRU, the module has not gone online and likely failed its self-test. Actions No action required. • Restart this controller from the other controller using SMU or the CLI. • Remove the controller and reinsert it. • Contact an authorized service provider for assistance. • Replace the controller. • Check the event log for specific information regarding the fault. • Isolate the fault. • Contact an authorized service provider for assistance. • If installing a controller FRU, restart the controller and check the event log for errors. Are both drive module LEDs, Online/Activity, and Fault/UID LEDs off? Answer Yes Possible Reasons • There is no power. • The drive is offline. • The drive is not configured. Actions • Check that the drive is fully inserted and latched in place, and that the enclosure is powered on. Chapter 5 Troubleshooting 57