HP AA988A HP StorageWorks 2012sa Modular Smart Array user guide (488320-002, J - Page 74

Management Host Requirements, Physical Requirements

Page 74 highlights

Management Host Requirements A local management host with at least one serial port connection is recommended for the initial installation and configuration of a controller enclosure. After you configure one or both of the controller modules with an Internet Protocol (IP) address, you then use a remote management host on an Ethernet network to configure, manage, and monitor. Note - Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations. Physical Requirements The floor space at the installation site must be strong enough to support the combined weight of the rack, controller enclosures, expansion enclosures, and any additional equipment. The site also requires sufficient space for installation, operation, and servicing the enclosures, and also requires sufficient ventilation to allow a free flow of air to all enclosures. Table A-1 and Table A-2 list enclosure dimensions and weights. Weights are based on an enclosure having 12 drive modules, two controller or expansion modules, and two power-and-cooling modules installed. Table A-1 Rackmount Enclosure Dimensions Specification Rackmount Height 2U 3.5 inches (8.9 cm) Width: • Chassis excluding mounting ears • Chassis including mounting ears 17.6 inches (44.7 cm) 18.9 inches (48.0 cm) Depth: • Chassis • To back of power-and-cooling module handle 21.8 inches (55.4 cm) 23.7 inches (60.2 cm) 74 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102

74
HP StorageWorks 2012sa Modular Smart Array user guide
May 2008
Management Host Requirements
A local management host with at least one serial port connection is recommended
for the initial installation and configuration of a controller enclosure. After you
configure one or both of the controller modules with an Internet Protocol (IP)
address, you then use a remote management host on an Ethernet network to
configure, manage, and monitor.
Note –
Connections to this device must be made with shielded cables with metallic
RFI/EMI connector hoods in order to maintain compliance with FCC Rules and
Regulations.
Physical Requirements
The floor space at the installation site must be strong enough to support the
combined weight of the rack, controller enclosures, expansion enclosures, and any
additional equipment. The site also requires sufficient space for installation,
operation, and servicing the enclosures, and also requires sufficient ventilation to
allow a free flow of air to all enclosures.
Table A-1 and Table A-2 list enclosure dimensions and weights. Weights are based
on an enclosure having 12 drive modules, two controller or expansion modules, and
two power-and-cooling modules installed.
Table A-1
Rackmount Enclosure Dimensions
Specification
Rackmount
Height
2U 3.5 inches (8.9 cm)
Width:
Chassis excluding mounting ears
Chassis including mounting ears
17.6 inches (44.7 cm)
18.9 inches (48.0 cm)
Depth:
• Chassis
To back of power-and-cooling module
handle
21.8 inches (55.4 cm)
23.7 inches (60.2 cm)