HP AE326A HP StorageWorks 1500 Modular Smart Array maintenance and service gui - Page 101
Failure of another drive during rebuild
UPC - 882780184954
View all HP AE326A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 101 highlights
Failure of another drive during rebuild If a non-correctable read error occurs on another physical drive in the array during the rebuild process, the Online LED of the replacement drive stops blinking and the rebuild abnormally terminates. If this situation occurs, restart the server and the storage system. The system may temporarily become operational long enough to allow recovery of unsaved data. In any case, locate the faulty drive, replace it, and restore data from backup. maintenance and service guide 101
Failure of another drive during rebuild
If a non-correctable read error occurs on another physical drive in the array during the rebuild process,
the Online LED of the replacement drive stops blinking and the rebuild abnormally terminates.
If this situation occurs, restart the server and the storage system. The system may temporarily become
operational long enough to allow recovery of unsaved data. In any case, locate the faulty drive, replace
it, and restore data from backup.
maintenance and service guide
101