HP AE326A HP StorageWorks 1500 Modular Smart Array maintenance and service gui - Page 52
Too Many, Volumes Detected, Spares Cleared, Access Control, Conflict Detected, Resources Exceeded
UPC - 882780184954
View all HP AE326A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
Message 123 TOO MANY VOLUMES DETECTED 124 SPARES CLEARED 125 ACCESS CONTROL CONFLICT DETECTED 126 ACCESS CONTROL RESOURCES EXCEEDED 150 BEACON ON Type Error Informational Error Error Informational Description Action The array controller only supports a maximum of 32 configured volumes. More volumes than that were detected at power up. This typically occurs when migrating a set of volumes from one array controller to a different array controller that already has configured volumes on it. The migrated volumes have not been added. Remove the migrated volumes and run the Array Configuration Utility (ACU). Delete any unneeded volumes until the number of existing volumes plus the number of migrated volumes is 32 or less. Add the migrated volumes back. A set of volumes has been migrated from one array controller to a different array controller that already has configured volumes on it. The migrated volumes have spares defined for them that conflict with the existing configuration. The defined spares have been deleted so as to allow the migration to proceed. Run the Array Configuration Utility (ACU) or MSA Command Line Interface (MSA-CLI) to reassign spare hard drives as needed. A set of volumes has been migrated from one array controller to a different array controller that already has configured volumes on it. The migrated volumes have access controls defined for them that conflict with the existing configuration. The access controls have been modified so as to allow the migration to proceed. Run the Array Configuration Utility (ACU) or MSA Command Line Interface (MSA-CLI) to check the new access controls and modify them if needed. A set of volumes has been migrated from one array controller to a different array controllers that already has configured volumes on it. The migrated volumes have access controls defined for them that conflict with the existing configuration. The access controls have been modified so as to allow the migration to proceed. Run the Array Configuration Utility (ACU) or MSA Command Line Interface (MSA-CLI) to check the new access controls and modify them if needed. The LEDs on the MSA and all connected hard drives are blinking because that array controller was selected for identification or configuration in a host-based application such as the ACU. 52 LCD panel and message descriptions