HP AE326A HP StorageWorks 1500 Modular Smart Array maintenance and service gui - Page 86

Installing the component

Page 86 highlights

CAUTION: Use appropriate precautions when handling Fibre Channel cables: • Touching the end of a Fibre Channel cable will either damage the cable or cause performance problems, including intermittent difficulties accessing the storage. • Whenever a Fibre Channel cable is not connected, replace the protective covers on the ends of the cable. • Make certain that the Fibre Channel cables are installed and supported so that no excess weight is placed on the connectors. This prevents damage to the connector and cable. Excess cable should be loosely coiled and tied out of the way, being careful not to coil the cable in a tight loop with a bend radius of less than 3 inches (7.62 cm). 1. Review all warnings, cautions, and preparation procedures as detailed in Warnings and precautions. 2. Disconnect the cable from the Fibre Channel I/O module. 3. Lift the port-colored Fibre Channel I/O module latch (1) and pull the Fibre Channel I/O module out of the chassis (2). 2 1 15498 Installing the component 1. Slide the replacement Fibre Channel I/O module into the MSA chassis bay until the module clicks into place. 15502 2. Either move the SFP transceiver from the old Fibre Channel I/O module or install a new SFP transceiver in the new module. For instructions on removing and installing an SFP, see Replacing a 2-Gb small form factor pluggable (SFP) transceiver. 3. Reconnect the cables. 86 Customer replaceable components

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120

CAUTION:
Use appropriate precautions when handling Fibre Channel cables:
Touching the end of a Fibre Channel cable will either damage the cable or cause performance
problems, including intermittent dif
culties accessing the storage.
Whenever a Fibre Channel cable is not connected, replace the protective covers on the ends of
the cable.
Make certain that the Fibre Channel cables are installed and supported so that no excess weight is
placed on the connectors. This prevents damage to the connector and cable. Excess cable should
be loosely coiled and tied out of the way, being careful not to coil the cable in a tight loop with a
bend radius of less than 3 inches (7.62 cm).
1.
Review all warnings, cautions, and preparation procedures as detailed in
Warnings and precautions
.
2.
Disconnect the cable from the Fibre Channel I/O module.
3.
Lift the port-colored Fibre Channel I/O module latch (
1
) and pull the Fibre Channel I/O module
out of the chassis (
2
).
2
1
15498
Installing the component
1.
Slide the replacement Fibre Channel I/O module into the MSA chassis bay until the module clicks
into place.
15502
2.
Either move the SFP transceiver from the old Fibre Channel I/O module or install a new SFP
transceiver in the new module. For instructions on removing and installing an SFP, see
Replacing a
2-Gb small form factor pluggable (SFP) transceiver
.
3.
Reconnect the cables.
86
Customer replaceable components