SVC Messages Chapter 2 System Messages and Recovery Procedures Send document comments to [email protected] Error Message SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_EXECVE_FAILED ) Internal error - program launch [chars] Explanation The process was unable to launch the IO program. Node was rebooted due to this error. Recommended Action If this error is repeated continously, 1. Re-install the code on the node. The node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest level of code. 3. If the error continues, ask IBM Product Support for assistance. Error Message SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_FORK_FAILED ) Internal error - fork failed [chars] Explanation The process was unable to launch the IO program. Node was rebooted due to this error. Recommended Action If this error is repeated continously, 1. Re-install the code on the node. The node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest level of code. 3. If the error continues, ask IBM Product Support for assistance. Error Message SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_INTERNAL_EXIT_LOGIC_ERR ) Internal error - bad exit code [chars] Explanation Node was warmstarted due to internal logic error. Recommended Action 1. Ensure that the software is at the latest level on the cluster. 2. Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac. Error Message SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_INTERNAL_UNKNOWN_EXEC_MODE ) Internal error - run mode [chars] Explanation Node was rebooted due to internal logic error. Recommended Action 1. Ensure that the software is at the latest level on the cluster. 2. Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac. Error Message SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_IOP_EXITED_DUE_TO_SIGNAL ) Internal error - signal caused exit [chars] Explanation The IO process exited because of a signal which was not caught. Node was warmstarted due to this error. Recommended Action 1. Ensure that the software is at the latest level on the cluster. 2. Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac. 2-644 Cisco NX-OS System Messages Reference OL-15994-03