HP AP775A Cisco NX-OS System Messages Reference (OL-15994-03, July 2009) - Page 762
Compact flash firmware CRC checksum might be bad on this module.
UPC - 884962062708
View all HP AP775A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 762 highlights
SYSTEMHEALTH Messages Chapter 2 System Messages and Recovery Procedures Send document comments to [email protected] Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_CRC_PROCESS_ERRORS: Compact flash firmware CRC checksum procedure failed on module [dec]. Reason [dec] Explanation Compact flash firmware CRC checksum procedure failed. Recommended Action Try restarting the cf-crc-check using system health clear-errors module cf-crc-check. If the condition still persists, schedule a downtime and replace the compact flash on the affected module. Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_CRC_TEST_FAILING: Compact flash firmware CRC checksum validation starting to fail on module [dec]. Explanation Compact flash firmware CRC checksum might be bad on this module. Recommended Action Schedule a downtime and replace the compact flash on the affected module. Do not attempt any hitless up/downgrades. Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_RECALLED: Compact Flash on module [dec] was recalled. Explanation The Compact flash model has data retention issues and needs to be replaced. Recommended Action Please schedule a downtime and replace the compact flash on this module. Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_REFLASH_INTERN_ERRORS: Compact Flash firmware re-flash procedure cannot proceed due to internal errors on module [dec]. Explanation Compact flash firmware re-flash procedure ended up in errors. Recommended Action Try restarting the test using system health clear-errors module cf-re-flash. If the condition still persists, schedule a downtime and replace the compact flash on the affected module. Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_REFLASH_TEST_FAILING: Compact flash firmware refresh procedure starting to fail on module [dec]. Explanation Compact flash might be dead on this module. Recommended Action Schedule a downtime and replace the compact flash on the affected module. Do not attempt any hitless up/downgrades. Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_UNRESPONSIVE: Recalled Compact Flash on module [dec] is unresponsive. Explanation The Compact flash model has data retention issues and needs to be replaced. Recommended Action Please schedule a downtime and replace the compact flash on this module. 2-724 Cisco NX-OS System Messages Reference OL-15994-03