HP Integrity Superdome SX1000 Internal Cabling Guide for HP Smart Array Contro
HP Integrity Superdome SX1000 Manual
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Integrity Superdome SX1000 manual content summary:
- HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 1
Internal Cabling Guide for HP Smart Array Controllers First Edition Manufacturing Part Number: 5971-4298 April 2006 © Copyright 2006 Hewlett-Packard Development Company, L.P. All rights reserved. - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 2
in this document is provided "as is" without warranty of any kind and is subject to change without notice. The warranties for HP products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 3
Right Hot Plug Hard Drives 31 Insight Manager 7 Hard Disk Drive Mapping 34 Configuring the Server Firmware and Software for RAID 35 4. Cabling for the HP Integrity rx7620 Server Installing the HP Smart Array 6402 or 6404 Controller Card 37 Recabling for RAID 38 Single Partition Configuration - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 4
RAID 74 8. Cabling for the HP Integrity rx2620 and rx2600 Servers Installing the HP Smart Array Controller Card 78 Recabling for RAID 79 Configuring the Server Firmware and Software for RAID 85 9. Cabling for the HP Integrity rx1620 Server Installing the HP Smart Array 6402 Controller Card 89 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 5
HP Integrity rx8620 Server. NOTE These instructions do not apply if you are connecting the controller card to an external mass storage box. Refer instead to the HP Smart Array Controller User Guide that shipped with your card. Table 1-1 shows the product numbers, descriptions and support matrix - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 6
Cabling for the HP Integrity rx8620 Server HP Smart Array Controller Card Ports HP Smart Array Controller Card Ports The ports on the HP Smart Array Controller Cards are labeled as shown in Table 1-2 Table 1-2 HP Smart Array Controller Card Port Labels Controller Card SA 5302/SA5304 SA 6402/ - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 7
Cabling for the HP Integrity rx8620 Server Single Partition RAID Configuration Single Partition RAID Configuration Figure 1-1 shows the correct cabling for a single partition configuration, as viewed from the front of the server. Figure 1-1 Smart Array Controller Card with Single Partition - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 8
HP Integrity rx8620 Server Single Partition RAID Configuration RAID Cabling for IO Chassis 0 (Top Left and Top Right Hot Plug Hard Drives) To set up the RAID cabling on the top left and top right hot plug hard drives, do the following: Step 1. Verify that the HP front of the server. See Figure 1-3 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 9
Cabling for the HP Integrity rx8620 Server Single Partition RAID Configuration Step 9. Unplug the existing SCSI ribbon cable for the top right HDD. This is the second connector from the right on the Mass Storage Bacplane when viewed from the front of the server. See Figure 1-3 Step 10. Fold the - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 10
HP Integrity rx8620 Server Dual Partition Configurations Dual Partition Configurations Figure 1-4 shows the correct cabling for a dual partition configuration, as viewed from the front of the server , do the following: Step 1. Verify that the HP Smart Array controller card is installed in PCI slot - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 11
Cabling for the HP Integrity rx8620 Server Dual Partition Configurations WARNING The cables must be routed along the side of the server. They must not lay on top of the flat SCSI ribbon cable tie on each cable makes it easier to identify the cables for installation and servicing. Chapter 1 7 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 12
HP Integrity rx8620 Server Dual Partition Configurations NOTE One end of each cable has a pull-tab connected to the SCSI connector which is labeled "This Connector to PCI Card". This end of the cable connects to the HP (this allows servicing of the other PCI cards). See Figure 1-6. 8 Chapter 1 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 13
Cabling for the HP Integrity rx8620 Server Dual Partition Configurations Figure 1-6 Smart Array Controller Card with Dual Partition Cabling Removable Media Cable Bundle Ties PCI Lift Handle Port 2/A1 and Bottom Right - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 14
the following mapping in IM7 when events occur on a target HDD, as shown in Table 1-4. Table 1-4 Hard Drive Mapping for the HP Integrity rx8620 Server SA5302 or 5304 Card Location HDD Identification HDD Location Cabinet I/O Bay I/O Chassis Slot Cabinet Cell Port SCSI ID Physical Drive - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 15
's internal hot swap drives, follow the procedures given in the Smart Array Controller User Guide: • Configure your HP Smart Array controller card in an HP Integrity server (use HP Smart Array utilities and command line options from the EFI shell) • Install and use the operating system-specific - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 16
Cabling for the HP Integrity rx8620 Server Configuring the Server Firmware and Software for RAID 12 Chapter 1 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 17
HP Integrity rx8640 Server. NOTE These instructions do not apply if you are connecting the controller card to an external mass storage box. Refer instead to the HP Smart Array Controller User Guide that shipped with your card. Table 2-1 shows the product numbers, descriptions and support matrix - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 18
Cabling for the HP Integrity rx8640 Server Single Partition RAID Configuration Single Partition RAID Configuration Figure 2-1 shows the correct cabling for a single partition configuration, as viewed from the front of the server. Figure 2-1 Smart Array Controller Card with Single Partition - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 19
HP Integrity rx8640 Server Single Partition RAID Configuration RAID Cabling for IO Chassis 0 (Top Left and Top Right Hot Plug Hard Drives) To set up the RAID cabling on the top left and top right hot plug hard drives, do the following: Step 1. Verify that the HP front of the server. See Figure 2-3 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 20
Cabling for the HP Integrity rx8640 Server Single Partition RAID Configuration Step 9. Unplug the existing SCSI ribbon cable for the top right HDD. This is the second connector from the right on the Mass Storage Bacplane when viewed from the front of the server. See Figure 2-2 Step 10. Fold the - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 21
Cabling for the HP Integrity rx8640 Server Dual Partition Configurations Dual Partition Configurations This section gives instructions for the installation of a second Smart Array Controller Card into the server. This will provide a dual partition configuration in the server. Figure 2-4 shows the - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 22
Cabling for the HP Integrity rx8640 Server Dual Partition Configurations Step 5. Route the cables as shown in Figure 2-3 towards the front of the server and over to the Mass Storage Backplane connectors. WARNING The cables must be routed along the side of the server. They must not lay on top of - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 23
Cabling for the HP Integrity rx8640 Server Dual Partition Configurations Figure 2-6 Smart Array Using a different color tie on each cable makes it easier to identify the cables for installation and servicing. NOTE One end of each cable has a pull-tab connected to the SCSI connector which is - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 24
HP Integrity rx8640 Server Dual Partition Configurations Step 4. Plug the end of one of the cables with the pull-tab into the SCSI connector Port A2 on the Smart Array card (Port 1 is near the rear of the server and maintain the slack (this allows servicing of the other PCI cards). 20 Chapter 2 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 25
Cabling for the HP Integrity rx8640 Server Dual Partition Configurations Figure 2-7 Smart Array Controller Card with Dual Partition Cabling Removable Media Cable Bundle Ties PCI Lift Handle Port A1 and Bottom Right - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 26
the following mapping in IM7 when events occur on a target HDD, as shown in Table 2-2. Table 2-2 Hard Drive Mapping for the HP Integrity rx8620 Server SA5302 or 5304 Card Location HDD Identification HDD Location Cabinet I/O Bay I/O Chassis Slot Cabinet Cell Port SCSI ID Physical Drive - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 27
's internal hot swap drives, follow the procedures given in the Smart Array Controller User Guide: • Configure your HP Smart Array controller card in an HP Integrity server (use HP Smart Array utilities and command line options from the EFI shell) • Install and use the operating system-specific - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 28
Cabling for the HP Integrity rx8640 Server Configuring the Server Firmware and Software for RAID 24 Chapter 2 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 29
Integrity rx8620 or rx8640 server. NOTE These instructions do not apply if you are connecting the controller card to an external mass storage box. Refer instead to the HP Smart Array Controller User Guide that shipped with your card. Table 3-1 shows the product numbers, descriptions and support - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 30
Notation Port 1/A2 Port 2/A1 Port Location Port near bulkhead Port near center of card Installing the HP Smart Array Controller Card Step 1. If the server is running, shut down the OS, power off the server, and unplug the power cords. Step 2. Remove the top cover of the SEU. Step 3. If only one - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 31
Cabling for the Server Expansion Unit Single Partition RAID Configuration Single Partition RAID Configuration Figure 3-1 shows the correct cabling for a single partition configuration, as viewed from the front of - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 32
Cabling for the Server Expansion Unit Single Partition RAID Configuration RAID Cabling for IO Chassis 0 (Top Left and Top Right Hot Plug Hard Drives) To set up the RAID cabling on the top left and top right hot plug hard drives, do the following: Step 1. Verify that the HP Smart Array controller - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 33
for the top right HDD. This is the second connector from the right on the Mass Storage Bacplane when viewed from the front of the server. See Figure 3-3 Step 10. Fold the SCSI connector on the ribbon cable so it will lay in front of the connector on the Mass Storage - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 34
top left and top right hot plug hard drives, do the following: Step 1. Verify that the HP Smart Array controller card is installed in PCI slot 8 of the IO Chassis 0. Step 2. Retrieve two in Figure 3-3 towards the front of the server and over to the Mass Storage Backplane connectors. 30 Chapter 3 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 35
left and bottom right hot plug hard drives, do the following, from the front of the server: Step 1. Verify that the HP Smart Array controller card is installed in PCI slot 8 of IO Chassis 1. Step 2. Retrieve cable makes it easier to identify the cables for installation and servicing. Chapter 3 31 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 36
Server Expansion Unit Dual Partition Configurations NOTE One end of each cable has a pull-tab connected to the SCSI connector which is labeled "This Connector to PCI Card". This end of the cable connects to the HP and maintain the slack (this allows servicing of the other PCI cards). 32 Chapter 3 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 37
Cabling for the Server Expansion Unit Dual Partition Configurations Figure 3-6 Smart Array Controller Card with Dual Partition Cabling Removable Media Cable Bundle Ties PCI Lift Handle Port 2 and Bottom Right HDD Cable Connections Port 1 and Bottom Left HDD Cable Connections Chapter 3 33 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 38
the following mapping in IM7 when events occur on a target HDD, as shown in Table 3-4. Table 3-4 Hard Drive Mapping for the HP Integrity rx8620 Server SA5302 or 5304 Card Location HDD Identification HDD Location Cabinet I/O Bay I/O Chassis Slot Cabinet Cell Port SCSI ID Physical Drive - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 39
's internal hot swap drives, follow the procedures given in the Smart Array Controller User Guide: • Configure your HP Smart Array controller card in an HP Integrity server (use HP Smart Array utilities and command line options from the EFI shell) • Install and use the operating system-specific - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 40
Cabling for the Server Expansion Unit Configuring the Server Firmware and Software for RAID 36 Chapter 3 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 41
controller card to the internal hard drives of an HP Integrity rx7620 Server. NOTE These instructions do not apply if you are connecting the controller card to an external mass storage box. Refer instead to the HP Smart Array Controller User Guide that shipped with your card. The Smart Array 6400 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 42
plug drives for the HP Integrity rx7620 server are connected to the integrated SCSI card as follows (when viewed from the front of the server): • The top left kit (A7027-63001). Then follow the appropriate set of instructions given below. Single Partition Configuration Figure 4-1 shows the correct - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 43
HP Integrity rx7620 Server Recabling for RAID Setting up RAID Cabling for IO Chassis 1 (Top Left and Top Right Hot Plug Hard Drives) To set up the RAID cabling on the top left and top right hot plug hard drives, do the following: Step 1. Verify that the HP slack (this allows servicing of the other - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 44
Cabling for the HP Integrity rx7620 Server Recabling for RAID Figure 4-2 Smart Array 6402 Controller Card with Single Partition Cabling Port A2 and Top Left HDD Cabling Port A1 and Top Right HDD Cabling 40 Chapter 4 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 45
Cabling for the HP Integrity rx7620 Server Recabling for RAID Dual Partition Configurations Figure 4-3 shows the correct cabling for a dual partition configuration, as viewed from the front of the server. Figure 4-3 Smart Array 6402 or 6404 Controller Card with Dual Partition Cabling Setting up - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 46
HP Integrity rx7620 Server wrap a Kwik Wrap around it to maintain the slack (this allows servicing of the other PCI cards). Setting up RAID Cabling for IO server: Step 1. Verify that the HP Smart Array 6402 or 6404 controller card is installed in PCI slot 0-8. Refer to HP Smart Array 6400 User Guide. - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 47
Cabling for the HP Integrity rx7620 Server Recabling for RAID Figure 4-4 Smart Array 6402 or 6404 Controller Card with Dual Partition Cabling Port A2 and Top Left HDD Cabling Port A1 and Bottom HDDs Cabling Port A1 and Top Right HDD Cabling Chapter 4 43 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 48
internal hot swap drives, follow the procedures given in the Smart Array 6400 Controller User Guide: • Configure your HP Smart Array 6402 or 6404 controller card in an HP Integrity server (use HP Smart Array 6400 utilities and command line options from the EFI shell) • Install and use the operating - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 49
controller card to the internal hard drives of an HP Integrity rx7640 Server. NOTE These instructions do not apply if you are connecting the controller card to an external mass storage box. Refer instead to the HP Smart Array Controller User Guide that shipped with your card. The Smart Array 6400 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 50
Cabling for the HP Integrity rx7640 Server Recabling for RAID • The bottom right hard drive has a SCSI connector cabled to Core I/O slot 8 cell 0 LAN SCSI card. To use RAID with your hot plug drives, you must reconfigure the internal SCSI cables as instructed and use the Cable kit (A7027-63001). - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 51
Cabling for the HP Integrity rx7640 Server Recabling for RAID Setting up RAID Cabling for IO Chassis 1 (Top Left and Top Right Hot Plug Hard Drives) To set up the RAID cabling on the top left and top right hot plug hard drives, do the following: Step 1. If the server is running, shut down the - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 52
Cabling for the HP Integrity rx7640 Server Recabling for RAID Step 9. Carefully route the round SCSI cable through the cable guide attached to the system backplane to the front of the server. The cable follows the same path as the flat SCSI ribbon cable already installed in the server. See Figure - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 53
Cabling for the HP Integrity rx7640 Server Recabling for RAID Step 18. Arrange the new cable so that all of the slack is located in the PCI area. Step 19. Loop the cable slack and wrap a Kwik Wrap around it to maintain the slack. This allows servicing of the other PCI cards. See Figure 5-5. Figure - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 54
Cabling for the HP Integrity rx7640 Server Recabling for RAID Dual Partition Configuration Figure 5-1 shows the correct cabling for a dual partition configuration, as viewed from the front of the server. Figure 5-6 Single Partition RAID Cabling 50 Chapter 5 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 55
the HP Integrity rx7640 Server Recabling for RAID Setting up RAID Cabling for Dual Partitions To set up the RAID cabling do the following: Step 1. If the server is running, shut down the OS, power off the server, and unplug the power cords. Step 2. Remove the top and left covers of the server. NOTE - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 56
Cabling for the HP Integrity rx7640 Server Recabling for RAID Figure 5-7 SCSI Cables Routed Through PCI Card Cage Handle Step 12. Carefully route the round SCSI cables through the cable guide attached to the system backplane to the front of the server. The cable follows the same path as the flat - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 57
Figure 5-9 Folded SCSI Connector Cabling for the HP Integrity rx7640 Server Recabling for RAID Step 14. Plug a new cable into the mass storage and wrap a Kwik Wrap around it to maintain the slack. This allows servicing of the other PCI cards. See Figure 5-10 and Figure 5-11. Chapter 5 53 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 58
Cabling for the HP Integrity rx7640 Server Recabling for RAID Figure 5-10 Smart Array 6402 Controller Card with Dual Partition Cabling Chassis 1 Port A2 and Top Left HDD Cabling Port A1 and Top Right HDD Cabling 54 Chapter 5 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 59
Cabling for the HP Integrity rx7640 Server Recabling for RAID Figure 5-11 Smart Array 6402 Controller Card with Dual Partition Cabling Chassis 0 Port A2 and Bottom Left HDD Cabling Port A1 and - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 60
internal hot swap drives, follow the procedures given in the Smart Array 6400 Controller User Guide: • Configure your HP Smart Array 6402 or 6404 controller card in an HP Integrity server (use HP Smart Array 6400 utilities and command line options from the EFI shell) • Install and use the operating - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 61
controller card to the internal hard drives of an HP Integrity rx5670 Server. NOTE These instructions do not apply if you are connecting the controller card to an external mass storage box. Refer instead to the HP Smart Array Controller User Guide that shipped with your card. The Smart Array 5300 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 62
Cabling for the HP Integrity rx5670 Server Figure 6-2 Smart Array 5304 Controller Card NOTE If an HP Server rx5670 is ordered from the factory along with an internal RAID option (with the HP Smart Array controller card and extension cable A9828-63001 pre-installed), this extension cable connects - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 63
HP Integrity rx5670 Server Installing the HP Smart Array 5302 or 5304 Controller Card Installing the HP Smart Array 5302 or 5304 Controller Card Step 1. If the server is running, shut down the OS, power off the server width, flat-headed screwdriver into the side service bay along the top of the PCI - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 64
Cabling for the HP Integrity rx5670 Server Installing the HP Smart Array 5302 or 5304 Controller Card Figure 6-4 PCI Card Separator/Extractor 1 Step 4. Install the HP Smart Array 5302 or 5304 controller card in PCI Slot 4 (see Figure 6-5). When finished, you should have the following cards in the - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 65
Figure 6-5 PCI Card Order Cabling for the HP Integrity rx5670 Server Installing the HP Smart Array 5302 or 5304 Controller Card Chapter 6 61 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 66
Cabling for the HP Integrity rx5670 Server Recabling for RAID Recabling for RAID From the factory, the internal hot plug drives for the HP rx5670 server are connected to the integrated SCSI as follows (see Figure 6-6 and Figure 6-7): • The MP/SCSI board in PCI slot 1 has a SCSI connector cabled to - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 67
Cabling for the HP Integrity rx5670 Server Recabling for RAID NOTE To connect drives A, B, C, and D, follow all steps in both of the sections described below. Setting Up RAID on Hot Plug Drives A and B Step 1. Confirm the HP Smart Array 5302 or 5304 controller card is installed in PCI slot 4. See - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 68
internal hot swap drives, follow the procedures given in the Smart Array 5300 Controller User Guide: • Configure your HP Smart Array 5302 or 5304 controller card in an HP Integrity server (use HP Smart Array 5300 utilities and command line options from the EFI shell) • Install and use the operating - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 69
6404 controller card to the internal hard drives of an HP 9000 rp3440 server. NOTE These instructions do not apply if you are connecting the controller card to an external mass storage box. Refer instead to the HP Smart Array Controller User Guide that shipped with your card. The Smart Array 6400 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 70
card installed in PCI slot 3. The additional cable (A7231-63025) is placed in the server top tray. The internal hot plug drive 2 is still connected to the integrated SCSI controller. PORT 2 of the HP Smart Array controller card is still available to connect the external StorageWorks mass storage or - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 71
external RAID mass storage. Installing the HP Smart Array Controller Card Step 1. If the server is running, shut down the OS, power off the server, and unplug the power cord. Step 2. Remove the metal system cover as described in the server's operation and maintenance guide. Step 3. Lift the PCI cage - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 72
for the HP 9000 rp3440 Server Installing the HP Smart Array Controller Card Step 4. Grasp the PCI cage cover and slide it away from the bulkhead end of the PCI cage. Lift the cover off the PCI cage as shown in Figure 7-3. Figure 7-3 Removing the PCI Cage Board Cover Step 5. Install the HP Smart - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 73
HP Smart Array controller card is not pre-installed in your server from the factory, then the rp3440 internal hard drives are connected to the integrated server) B 2 A 1 0 Your server's internal hard disk drives can be set up for single or dual channel RAID support. To use RAID with your server - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 74
Cabling for the HP 9000 rp3440 Server Recabling for RAID Figure 7-7 Location of Fan 2 and Fan 3 3 Front of server 2 Step 2. To remove a fan, grasp the fan module with your index finger and thumb and lift it out of its slot. Note that each of - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 75
Cabling for the HP 9000 rp3440 Server Recabling for RAID Step 4. Unplug one or both of the SCSI cables connected to the hard drive backplane (see Figure 7-5), depending upon whether you want to use one or both channels of the HP Smart Array controller card: • Single channel: unplug backplane SCSI - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 76
Cabling for the HP 9000 rp3440 Server Recabling for RAID Figure 7-12 Removing the iLO Manageability configuring for single or dual channel support: a. Single Channel Support: Plug the end of the A7231-63024 single channel cable labeled "PORT 1" into PORT A2 of the HP Smart Array controller card (see - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 77
Cabling for the HP 9000 rp3440 Server Recabling for RAID other part of the cables which are labeled Channel A (bottom) and Channel B (top) should exit the PCI cage flush against where the - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 78
the installation and set up RAID for your server's internal hot swap drives, follow the procedures given in the HP Smart Array 6402/6404 Controller Installation Guide: • Configure your HP Smart Array controller card in an HP 9000 server (use HP Smart Array utilities) • Install and use the operating - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 79
HP Integrity rx2620 or rx2600 Server. NOTE These instructions do not apply if you are connecting the controller card to an external mass storage box. Refer instead to the HP Smart Array Controller User Guide 5304, and 6402 are supported on HP Integrity rx2620 and rx2600 servers. Table 8-1 shows - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 80
Cabling for the HP Integrity rx2620 and rx2600 Servers Figure 8-1 Smart Array 5302 Controller Card Figure 8-2 Smart Array 5304 Controller Card 76 Chapter 8 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 81
Cabling for the HP Integrity rx2620 and rx2600 Servers Figure 8-3 Smart Array 6402 Controller Card Table 8-2 identifies the major components of the Smart Array 6402 controller card. Table 8-2 SA 6402 Controller Card Components Item - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 82
the HP Integrity rx2620 and rx2600 Servers Installing the HP Smart HP Smart Array Controller Card Step 1. If the server is running, shut down the OS, power off the server, and unplug the power cord. Step 2. Remove the metal system cover as described in the server's operation and maintenance guide - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 83
Cabling for the HP Integrity rx2620 and rx2600 Servers Recabling for RAID Step 4. Grasp the PCI cage cover and slide it away from the bulkhead end of the PCI cage. Lift the cover off the PCI cage as shown in Figure 8-5. Figure 8-5 Removing the PCI Cage Board Cover Step 5. Install the HP Smart Array - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 84
for the HP Integrity rx2620 and rx2600 Servers Recabling for RAID Figure 8-7 Default Cabling for Internal Hard Drives B A Figure 8-8 Physical Drive Location (front of server) B 2 A 1 0 Your server's internal hard disk drives can be set up for single or dual channel RAID support. To use - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 85
Cabling for the HP Integrity rx2620 and rx2600 Servers Recabling for RAID Step 2. To remove a fan, grasp (see Figure 8-7), depending upon whether you want to use one or both channels of the HP Smart Array controller card: • Single channel: unplug backplane SCSI cable Channel A (bottom) connector - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 86
Cabling for the HP Integrity rx2620 and rx2600 Servers Recabling for RAID Step 6. Use a T-15 torx driver to located on the far left and right sides of the card when viewed from the back of the server chassis. Step 9. Remove the two connector-screws for the 25-Pin Management Port located on the right - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 87
Cabling for the HP Integrity rx2620 and rx2600 Servers Recabling for RAID Step 11. Disconnect and other end of the cable into the hard drive backplane yet. You do this later. b. Dual Channel Support: For 5300 series cards, plug the ends of the A7231-63025 dual channel cable labeled "PORT 1" and - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 88
Cabling for the HP Integrity rx2620 and rx2600 Servers Recabling for RAID Figure 8-16 Single Channel RAID Cabling 14. Place the PCI cage back into the system. The RAID cable(s) must be flush against the server chassis as they exit the PCI cage cable channel (see Item 1 in Figure 8-19). They must - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 89
To complete the installation and set up RAID for your server's internal hot swap drives, follow the procedures given in the HP Smart Array Controller User Guide: • Configure your HP Smart Array controller card in an HP Integrity server (use HP Smart Array utilities and command line options from the - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 90
Cabling for the HP Integrity rx2620 and rx2600 Servers Configuring the Server Firmware and Software for RAID 86 Chapter 8 - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 91
HP Integrity rx1620 Server. NOTE These instructions do not apply if you are connecting the controller card to an external mass storage box. Refer instead to the HP Smart Array Controller User Guide cache. Only Model 6402 is supported on the HP Integrity rx1620 server. Table 9-1 shows the product number - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 92
Cabling for the HP Integrity rx1620 Server Table 9-2 identifies the major components of the Smart Array 6402 controller card. Table 9-2 SA 6402 Controller Card Components Item ID Description 1 Internal SCSI connector, port - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 93
Cabling for the HP Integrity rx1620 Server Installing the HP Smart Array 6402 Controller Card Installing the HP Smart Array 6402 management processor card is installed in the server, follow the instructions provided in the server's Operation and Maintenance Guide to remove the card, allowing access - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 94
Cabling for the HP Integrity rx1620 Server Installing the HP Smart Array 6402 Controller Card Figure 9-3 Cable accessory cards previously removed from PCI slot 2. Step 12. Install the PCI cage into the server chassis. Step 13. Route the SCSI cable under the power supply bracket. See Figure 9-4. - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 95
not block fans Route over IDE cable (if present) Step 15. Complete the installation by following the instructions provided in the HP Integrity rx1600 Operation and Maintenance Guide for closing up the server, installing it in a rack, and powering it up. To enable RAID, refer to the controller card - HP Integrity Superdome SX1000 | Internal Cabling Guide for HP Smart Array Contro - Page 96
Cabling for the HP Integrity rx1620 Server Installing the HP Smart Array 6402 Controller Card 92 Chapter 9
Internal Cabling Guide
for HP Smart Array Controllers
First Edition
Manufacturing Part Number: 5971-4298
April 2006
© Copyright 2006
Hewlett-Packard Development Company, L.P.
All rights reserved.