HP Integrity Superdome SX1000 Internal Cabling Guide for HP Smart Array Contro - Page 34
Smart Array Controller Card with Dual Partition Cabling, Mass Storage Backplane
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
Cabling for the Server Expansion Unit Dual Partition Configurations Dual Partition Configurations Figure 3-4 shows the correct cabling for a dual partition configuration, as viewed from the front of the SEU. Figure 3-4 Smart Array Controller Card with Dual Partition Cabling Port 1/A2 Port 2/A1 Port 1/A2 Port 2/A1 Mass Storage Backplane Connections RAID Cabling for IO Chassis 0 (Top Left and Top Right Hot Plug Hard Drives) To set up the RAID cabling on the top left and top right hot plug hard drives, do the following: Step 1. Verify that the HP Smart Array controller card is installed in PCI slot 8 of the IO Chassis 0. Step 2. Retrieve two cables from the cable kit (A7027-63001). Step 3. Identify the new cables using the colored cable ties which are also contained in the cable kit. For each cable, use two of the same color, one on each end. NOTE One end of each cable has a pull-tab connected to the SCSI connector which is labeled "This Connector to PCI Card". This end of the cable connects to the HP Smart Array card. Step 4. Plug the end of one of the cables with the pull-tab into the SCSI connector Port 1/A2 on the Smart Array card. Repeat for SCSI connector Port 2A1. Step 5. Route the cables as shown in Figure 3-3 towards the front of the server and over to the Mass Storage Backplane connectors. 30 Chapter 3