HP StorageWorks 2/24 FW 07.00.00/HAFM SW 08.06.00 McDATA Products in a SAN Env - Page 144
Verify FICON devices log back in, Verify cascaded FICON operation
View all HP StorageWorks 2/24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 144 highlights
Planning Considerations for Fibre Channel Topologies 3 NOTE: An cascaded switch is a fabric director or switch connected to a destination control unit and an entry switch. c. Run the IOCP to create an input/output configuration data set (IOCDS). The switch ID (CHPID macroinstructions) and 2-byte link address (control unit macroinstructions) are updated in the IOCDS. Refer to the IBM FICON Native Implementation and Reference Guide (SG24-6266) for additional information. 10. Verify FICON devices log back in - Inspect the Node List View and verify FICON devices (channels and control units inspected in step 5) log back in to the fabric as expected. 11. Verify cascaded FICON operation - Have the customer verify operation of established logical FICON paths between channels and control units, and verify that cascaded FICON traffic is transmitted through the fabric as expected. 3-58 McDATA Products in a SAN Environment - Planning Manual