HP StorageWorks 2/24 FW 07.00.00/HAFM SW 08.06.00 McDATA Products in a SAN Env - Page 289
Power Requirements, Intrepid 10000 Director
View all HP StorageWorks 2/24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 289 highlights
Product Specifications Power Requirements McDATA products have the following nominal power requirements: Intrepid 6064 Director: Input voltage: 100 to 240 VAC. Input current: 2.0 amps at 208 VAC. Input frequency: 47 to 63 Hz. Intrepid 6140 Director: Input voltage: 200 to 240 VAC. Input current: 4.2 amps at 208 VAC. Input frequency: 47 to 63 Hz. Intrepid 10000 Director: Input voltage: 180 to 270 VAC. Input current: 12.0 amps at 208 VAC. NOTE: The Intrepid 10000 Director must be connected directly to facility power outlets. The director draws a current of 32 amperes at power-on, and must not be connected to power strips in the FC-512 Fabricenter equipment cabinet. Input frequency: 47 to 63 Hz. Sphereon 3232 Switch: Input voltage: 100 to 240 VAC. Input current: 1.3 amps at 208 VAC. Input frequency: 47 to 63 Hz. Sphereon 4300 Switch: Input voltage: 100 to 240 VAC. Input current: 0.4 amps at 208 VAC. Input frequency: 47 to 63 Hz. Sphereon 4500 Switch: Input voltage: 100 to 240 VAC. Input current: 0.5 amps at 208 VAC. Input frequency: 47 to 63 Hz. Product Specifications A-3