HP StorageWorks 2/32 Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 374
miniCycle, Synopsis, Description
View all HP StorageWorks 2/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 374 highlights
2 Note: Enter commands in lowercase only; mixed case is for readability. miniCycle miniCycle Runs a functional test of internal and external transmit and receive paths at full speed. Synopsis minicycle [--slot slotnumber][-nmegs count][-lb_mode mode][-spd_mode mode][-ports itemlist] Description Use this command to verify the intended functional operation of an ASIC pair (miniswitch) at the maximum or selected speed by setting up the routing hardware so that frames received by port M are retransmitted by way of port N. Likewise, frames received by port N are retransmitted by way of port M. Each port M sends two frames to its partner, port N. This test is run as a series of eight path tests. Each port on the ASIC pair is exchanging frames with one port on the adjacent ASIC in the same miniswitch. At the end of a path test, the frames are captured and the routing is changed so that each port exchanges frames with the next port on the adjacent ASIC of the same miniswitch. Unlike implementation of the spinSilk command, a port is only exchanging frames with one other port at a time under the miniCycle command. Just as with spinSilk, all ports are active and exchanging frames simultaneously with miniCycle. The path number being tested determines the partner port N for each port M (bold and italicized in the following example): path 0: 0-8, 1-9, 2-10, 3-11, 4-12, 5-13, 6-14, 7-15 path 1: 7-8, 0-9, 1-10, 2-11, 3-12, 4-13, 5-14, 6-15 path 2: 6-8, 7-9, 0-10, 1-11, 2-12, 3-13, 4-14, 5-15 path 3: 5-8, 6-9, 7-10, 0-11, 1-12, 2-13, 3-14, 4-15 path 4: 4-8, 5-9, 6-10, 7-11, 0-12, 1-13, 2-14, 3-15 path 5: 3-8, 4-9, 5-10, 6-11, 7-12, 0-13, 1-14, 2-15 path 6: 2-8, 3-9, 4-10, 5-11, 6-12, 7-13, 0-14, 1-15 path 7: 1-8, 2-9, 3-10, 4-11, 5-12, 6-13, 7-14, 0-15 Note The port numbers are relative to the ASIC pair. This test does not route frames from one ASIC-pair to another. Ports cabled to other ports fail if port loopback mode is selected, and the port must have media and loopback plugs installed. For best coverage, you should use self-loopback plugs and port loopback mode (-lb_mode 1), as each port's external connectivity will be tested. The frames are continuously transmitted and received in all ports in parallel. The port LEDs flicker green rapidly while the test runs. The path test method is as follows: 1. Clear port statistics and error counters. 2. Enable ports for specified self-loopback mode. 3. Configure up the routing table so that when port M receives frames, the frames are routed back to the partner port N and vice versa. 4. Transmit two frames by way of port M and two frames by way of port N. The following four patterns will be used for the four frames, one pattern each: • 1000 bytes of CSPAT • 480 bytes of RDRAM_PAT • 2112 bytes of BYTE_LFSR 2-340 Fabric OS Command Reference Manual Publication Number: 53-1000240-01