HP Surestore 15 Slot with DLT7000 HP SureStore DLT Tape Library Models 4115w/4 - Page 66
Setting SCSI IDs
View all HP Surestore 15 Slot with DLT7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 66 highlights
Table 3-2 Operating the Library Setting and Viewing SCSI IDs Setting SCSI IDs 1 2 → ADMIN * → SCSI IDs * → SET IDs * A SCSI ID is required for the robotics controller and each drive. The default IDs are shown in Table 3-1 on page 3-11. The following configuration choices are available: SCSI Address Configuration Options Number of Drives SCSI Bus Addresses Available 1 13 addresses are available on bus 1. (Drive 1 uses one address and the library controller uses 1 address.) 2 If buses 1 and 2 are connected to separate host SCSI cards: • 13 addresses are available on bus 1 for other devices. • 14 addresses are available on bus 2 for other devices. If buses 1 and 2 are daisy-chained: • 12 addresses are available on the bus for other devices. To change the current SCSI address settings: 1. Verify that the drive status displays (if not, press CANCEL until it does). 2. Press NEXT until ADMIN * displays, then press ENTER. 3. Enter the three-part numerical password (see "Entering the Administration Menu Password" on page 3-9). 4. Press NEXT until SCSI IDs * displays, then press ENTER. 5. SET IDs * displays. Press ENTER. LIB BUS # ID # or DRV # BUS # ID # displays. LIB BUS # ID # stands for the current SCSI ID of the robotics controller. DRV # BUS # ID # is the current SCSI ID setting for the drive number and its associated bus #. 6. Press NEXT until the setting to change displays, then press ENTER. 3-12