HP Surestore 64 FW 05.01.00 and SW 07.01.00 HP StorageWorks Embedded Web Serve - Page 124

of Unique Zone Members, Error 75: Invalid Zone Set

Page 124 highlights

Error Messages Table 9: Embedded Web Serve Messages (Continued) Message Error 72: No Backup FRU Error 73: Port Not Installed Error 74: Invalid Number of Zones Error 75: Invalid Zone Set Size Error 76: Invalid Number of Unique Zone Members Error 77: Not Allowed While Port Is Failed Error 78: System Error Light On Description The FRU cannot be swapped because a backup FRU is not installed. The port specified is not installed on this product. The specified zone set contains less than one zone or more than the maximum number of zones allowed for this product. The zone set entered exceeds switch NVRAM limitations. The zone entered contains more than the maximum number of zone members allowed per zone set for this product. The port selected is in a failed or inactive state, or is in need of service. This unit is not able to beacon because the system error light is on. Action Insert a backup FRU and resubmit the request or consult the installation or service manual for this product for appropriate action. Consult the installation/service manual on installing a port optic. A zone set must contain at least one zone to be considered valid. Add or remove zones accordingly to meet specified requirements. Reduce the size of the zone set to meet specified requirements. This can be a reduction in the number of zones in the zone set, a reduction of members in a zone, or a reduction of zone name lengths. Reduce the number of members in one or more zones and resubmit the command. Consult the installation/service manual for appropriate action. You must clear the system error light before unit beaconing may be enabled. Consult the installation/service manual for appropriate action. 124 Embedded Web Server User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146

Error Messages
124
Embedded Web Server User Guide
Error 72: No Backup FRU
The FRU cannot be
swapped because a
backup FRU is not
installed.
Insert a backup FRU and
resubmit the request or
consult the installation or
service manual for this
product for appropriate
action.
Error 73: Port Not
Installed
The port specified is not
installed on this product.
Consult the
installation/service
manual on installing a
port optic.
Error 74: Invalid Number
of Zones
The specified zone set
contains less than one
zone or more than the
maximum number of
zones allowed for this
product.
A zone set must contain
at least one zone to be
considered valid. Add or
remove zones accordingly
to meet specified
requirements.
Error 75: Invalid Zone Set
Size
The zone set entered
exceeds switch NVRAM
limitations.
Reduce the size of the
zone set to meet specified
requirements. This can be
a reduction in the number
of zones in the zone set, a
reduction of members in a
zone, or a reduction of
zone name lengths.
Error 76: Invalid Number
of Unique Zone Members
The zone entered contains
more than the maximum
number of zone members
allowed per zone set for
this product.
Reduce the number of
members in one or more
zones and resubmit the
command.
Error 77: Not Allowed
While Port Is Failed
The port selected is in a
failed or inactive state, or
is in need of service.
Consult the
installation/service
manual for appropriate
action.
Error 78: System Error
Light On
This unit is not able to
beacon because the
system error light is on.
You must clear the system
error light before unit
beaconing may be
enabled. Consult the
installation/service
manual for appropriate
action.
Table 9: Embedded Web Serve Messages (Continued)
Message
Description
Action