HP Surestore 64 FW 05.01.00 and SW 07.01.00 HP StorageWorks Embedded Web Serve - Page 125

Error 90: Invalid Port Type, Error 89: Not Allowed

Page 125 highlights

Error Messages Table 9: Embedded Web Serve Messages (Continued) Message Error 79: FRU Failed Error 81: Default Zone Enabled Error 82: Invalid Interop Mode Error 83: Not Allowed in Open Fabric Mode Error 88: Invalid Feature Key Length Error 89: Not Allowed in S/390 Mode Without the SANtegrity Feature Error 90: Invalid Port Type Description The specified FRU has failed. The request cannot be completed because the default zone is enabled The value entered for the interoperability mode is not valid. This request cannot be completed while this switch is operating in Open Fabric 1.0 mode. The feature key installed is longer than the maximum length allowed. Cannot configure port types in S/390 mode (FICON management style in HAFM) without installing SANtegrity. The port type configured is invalid. Action Consult the installation/service manual for appropriate action. Disable the default zone and resubmit the command. The interoperability mode for the director or switch must be mcdata (Homogenous Fabric) or open (Open Fabric 1.0). Make the appropriate changes and resubmit the command. Configure the interop mode to Homogenous Fabric mode. Be sure that the key has been entered correctly and resubmit. Contact your sales representative with any further problems. This command is only supported when the switch is in Open Systems mode (Open Systems management style in HAFM) or in S/390 mode (FICON management style in HAFM) with SANtegrity. A port may be configured to be an eport, gport, or fport. Be sure the port is configured appropriately and resubmit the command. Embedded Web Server User Guide 125

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146

Error Messages
125
Embedded Web Server User Guide
Error 79: FRU Failed
The specified FRU has
failed.
Consult the
installation/service
manual for appropriate
action.
Error 81: Default Zone
Enabled
The request cannot be
completed because the
default zone is enabled
Disable the default zone
and resubmit the
command.
Error 82: Invalid Interop
Mode
The value entered for the
interoperability mode is
not valid.
The interoperability mode
for the director or switch
must be mcdata
(Homogenous Fabric) or
open (Open Fabric 1.0).
Make the appropriate
changes and resubmit the
command.
Error 83: Not Allowed in
Open Fabric Mode
This request cannot be
completed while this
switch is operating in
Open Fabric 1.0 mode.
Configure the interop
mode to Homogenous
Fabric mode.
Error 88: Invalid Feature
Key Length
The feature key installed is
longer than the maximum
length allowed.
Be sure that the key has
been entered correctly
and resubmit. Contact
your sales representative
with any further problems.
Error 89: Not Allowed in
S/390 Mode Without the
SANtegrity Feature
Cannot configure port
types in S/390 mode
(FICON management
style in HAFM) without
installing SANtegrity.
This command is only
supported when the
switch is in Open Systems
mode (Open Systems
management style in
HAFM) or in S/390
mode (FICON
management style in
HAFM) with SANtegrity.
Error 90: Invalid Port Type
The port type configured
is invalid.
A port may be configured
to be an eport, gport, or
fport. Be sure the port is
configured appropriately
and resubmit the
command.
Table 9: Embedded Web Serve Messages (Continued)
Message
Description
Action