CLI Commands Output The LAN configuration data is displayed as a table that includes the following properties. IP Address Gateway Address Subnet Mask The IP address. The gateway address. The subnet mask. Output Example The output from the config.ip.show command displays as follows. IP Address: Gateway Address: Subnet Mask: 10.0.0.0 0.0.0.0 255.0.0.0 config.port.blocked Syntax blocked portNumber blockedState Purpose This command sets the blocked state for a port. Parameters This command has two required parameters. portNumber blockedState Specifies the port number. Valid values are: 0-63 for the FC-64 Specifies the blocked state for the port. Valid values are true and false. Boolean 1 and 0 may be substituted as values. config 23
config
23
CLI Commands
Output
The LAN configuration data is displayed as a table that includes the following properties.
Output Example
The output from the config.ip.show command displays as follows.
IP Address:
10.0.0.0
Gateway Address:
0.0.0.0
Subnet Mask:
255.0.0.0
config.port.blocked
Syntax
blocked portNumber blockedState
Purpose
This command sets the blocked state for a port.
Parameters
This command has two required parameters.
IP Address
The IP address.
Gateway Address
The gateway address.
Subnet Mask
The subnet mask.
portNumber
Specifies the port number. Valid values are:
0
–
63 for the FC-64
blockedState
Specifies the blocked state for the port. Valid values are
true
and
false
.
Boolean 1 and 0 may be substituted as values.