HP Surestore 64 HP Surestore Director FC-64 Command Line Interface User's Guid - Page 53
config.switch.priority, Command Example, Root>, Syntax, Purpose, Description, Parameters
View all HP Surestore 64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 53 highlights
CLI Commands Command Example Root> config switch prefDomainId 1 config.switch.priority Syntax priority switchPriority Purpose This command sets the switch priority. Description The switch must be set offline before this command is entered. Parameters This command has one parameter. switchPriority Specifies the switch priority. Valid values are: principal, default, or neverprincipal. principal - sets the numerical switch priority to 1. The switch with a priority of 1 becomes the principal switch; however, if two or more switches have a priority of 1, the switch with the lowest WWN becomes the principal switch. default - sets the numerical switch priority to 254. If no switch is set to principal, the switch with a priority 254 becomes the principal switch; however, if two or more switches have a priority of 254, the switch with the lowest WWN becomes the principal switch. neverprincipal - sets the numerical switch priority to 255. This switch is not able to become the principal switch. Note that at least one switch in a multiswitch fabric must have a switch priority value of principal or default. Note that the number codes 2-253 are not now in use. config 41