HP Surestore S10 Service and User Manual (Short- and Long-Wave) - Page 72

LED Indicators

Page 72 highlights

LED Indicators Table 2 LED Indications Label Power Fault Ports 1-10 LED Pattern and Color Indication Possible Causes steady - green Hub is powered on. Normal state flashing - green Power is intermittent. - Fibre Channel Manager is set to beacon (flash) the Power LED (normal state). - Line voltage is inadequate. - Hub is faulty. blank - off No power to hub. - Line has no voltage. - Hub is disconnected, or power cable is bad. - Hub is faulty. steady - amber Hub is running self-test. If light remains on after 20 seconds, hub failed self-test. If self-test fails, hub detected either: - A faulty fan module - A faulty hub blank - not on Self-test completed or power is off. (Power LED is also off.) Normal running or off state steady - green FC-AL connection to this port is valid. Normal state for a connected port blank - not on Port for this LED is inactive. Port is being bypassed because: - Port is not connected to another device. - Port was bypassed in Fibre Channel Manager. - Attached FC-AL device is faulty or turned off. - Port is faulty. - Cable or connector is faulty. 70 LED Indicators

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

70
LED Indicators
LED Indicators
Table 2
LED Indications
Label
LED Pattern
and Color
Indication
Possible Causes
Power
steady – green
Hub is powered on.
Normal state
flashing - green
Power is intermittent.
Fibre Channel Manager is set to beacon
(flash) the Power LED (normal state).
Line voltage is inadequate.
Hub is faulty.
blank – off
No power to hub.
Line has no voltage.
Hub is disconnected, or power cable is bad.
Hub is faulty.
Fault
steady – amber
Hub is running self-test.
If light remains on after
20 seconds, hub failed
self-test.
If self-test fails, hub detected either:
A faulty fan module
A faulty hub
blank – not on
Self-test completed or
power is off. (Power
LED is also off.)
Normal running or off state
Ports
1-10
steady – green
FC-AL connection to
this port is valid.
Normal state for a connected port
blank – not on
Port for this LED is
inactive.
Port is being bypassed because:
Port is not connected to another device.
Port was bypassed in Fibre Channel
Manager.
Attached FC-AL device is faulty or turned
off.
Port is faulty.