Icom IC-78 Instruction Manual - Page 19

Microphone compressor, VOX operation

Page 19 highlights

4 OPERATION ï Microphone compressor IC-78 has a built-in, low distortion Mic compressor circuit. This circuit increases your average talk power in SSB mode and is especially useful when the receiving station is having difficulty copying your signal. q Select USB or LSB mode. w Push [COMP] switch to turn mic compressor ON. [COMP] switch e Confirm the ALC level. • Push [SET] to select the ALC meter. • Speak into the microphone at a normal voice level. • If the ALC meter peak past the ALC zone, re-adjust the mic. gain. (p.16) • Be sure the mic gain is in the range of 20 to 50. ALC zone Adjust [MIC GAIN] so that the ALC meter reads within the ALC zone. Note: When the ALC meter peaks above the ALC zone, your transmitted voice may be distorted. • "COM" indicator appears. Appears when mic compressor is activated. ï VOX operation The VOX (Voice-operated Transmission) function switches between transmit and receive with your voice. This function provides an opportunity to input log entries into your computer, etc. while operating. q Select "VOX" in quick set mode. • Push [SET] for 1 sec. to select quick set mode. • Push [∫ UP]/[√ DN] to select "VOX". w Rotate the channel selector to turn VOX function ON. Rotate the channel selector OFF ON e Select "VOX GAIN" in quick set mode. • Push [∫ UP]/[√ DN] to select "VOX". r While speaking into the microphone, adjust [VOX GAIN] with the channel selector, until the trans- ceiver is transmitting. t Select "VOX DELY" in quick set mode. • Push [∫ UP]/[√ DN] to select "VOX Delay" t While speaking into the microphone, adjust [VOX DELY] as desired. y Select "ANTI-VOX" in quick set mode. • Push [∫ UP]/[√ DN] one or more times to select "AN VOX" u If the receive audio from the speaker switches the transceiver to transmit during receive, adjust the "ANTI-VOX" to the point where it has no effect. i Push [SET] to exit quick set mode. 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

17
4
OPERATION
ï
Microphone compressor
IC-78 has a built-in, low distortion Mic compressor
circuit. This circuit increases your average talk power
in SSB mode and is especially useful when the re-
ceiving station is having difficulty copying your signal.
q
Select USB or LSB mode.
w
Push [COMP] switch to turn mic compressor ON.
•“COM” indicator appears.
e
Confirm the ALC level.
•Push [SET] to select the ALC meter.
•Speak into the microphone at a normal voice level.
•If the ALC meter peak past the ALC zone, re-adjust the
mic. gain. (p.16)
•Be sure the mic gain is in the range of 20 to 50.
Note:
When the ALC meter peaks above the ALC
zone, your transmitted voice may be distorted.
The VOX (Voice-operated Transmission) function
switches between transmit and receive with your
voice. This function provides an opportunity to input
log entries into your computer, etc. while operating.
q
Select “VOX” in
quick set mode
.
•Push [SET] for 1 sec. to select
quick set mode
.
•Push [
UP]/[
DN] to select “VOX”.
w
Rotate the channel selector to turn VOX function
ON.
e
Select “VOX GAIN” in
quick set mode
.
•Push [
UP]/[
DN] to select “VOX”.
r
While speaking into the microphone, adjust [VOX
GAIN] with the channel selector, until the trans-
ceiver is transmitting.
t
Select “VOX DELY” in
quick set mode
.
•Push [
UP]/[
DN] to select “VOX Delay”
t
While speaking into the microphone, adjust [VOX
DELY] as desired.
y
Select “ANTI-VOX” in
quick set mode
.
•Push [
UP]/[
DN] one or more times to select “AN
VOX”
u
If the receive audio from the speaker switches the
transceiver to transmit during receive, adjust the
“ANTI-VOX” to the point where it has no effect.
i
Push [SET] to exit
quick set mode
.
ï
VOX operation
Rotate the
channel selector
ON
OFF
[COMP] switch
Adjust [MIC GAIN] so that the ALC
meter reads within the ALC zone.
ALC zone
Appears when
mic compressor
is activated.