Icom IC-78 Instruction Manual - Page 24

Filter setting

Page 24 highlights

4 OPERATION s Filter setting When an optional filter is installed, set the optional filters in initial set mode. Optional filters are not selected by default. (p. 33) D Optional filter setting q While pushing and holding [SET], push [PWR] to enter initial set mode. w Push [UP Y] or [Z DN] several times until "FIL" appears on the display. e Rotate the channel selector to select the installed filter. • "no," "52A," "53A," "96," "222" and "257" indicate no optional filter, FL-52A, FL-53A, FL-96, FL-222 and FL-257, respectively for 455 kHz IF filter selection. r Push [PWR] for 1 sec. to exit initial set mode. D Expanded filter selection The selectable filter combinations can be expanded by setting the expanded filter selection to ON. Then extra wide or narrow filter can be selected on desired mode. q While pushing and holding [SET], push [PWR] to enter initial set mode. w Push [UP Y] or [Z DN] several times until "EXP FIL" appears. e Rotate the channel selector to turn the expanded filter selection 'on'. • If 'on' is selected, the expanded filter selection can be used. • Wide/narrow filter selection r Push [UP Y] several times until "WIDE TT" or "NAR TT" appears on the display. t Push [MODE] several times to se- lect the desired mode. y Rotate the channel selector to se- lect a filter. u Repeat steps t and y to select IF filters for other modes, if de- sired. •The filter combinations are stored depending on operating modes. • Wide filter setting table SSB no FL-52A FL-53A FL-96 FL-222 FL-257 no no no 96 (2.8 kHz) no 257 (3.3 kHz) THU (6 kHz) THU (6 kHz) THU (6 kHz) THU (6 kHz) THU (6 kHz) THU (6 kHz) no no no 96 (2.8 kHz) no 257 (3.3 kHz) CW THU (6 kHz) THU (6 kHz) THU (6 kHz) THU (6 kHz) THU (6 kHz) THU (6 kHz) no no no 96 (2.8 kHz) no 257 (3.3 kHz) RTTY THU (6 kHz) THU (6 kHz) THU (6 kHz) THU (6 kHz) THU (6 kHz) THU (6 kHz) - - - - - - AM • Narrow filter setting table : default SSB no FL-52A FL-53A FL-96 FL-222 FL-257 - no no - 222 (1.8 kHz) - 52A (500 Hz) 53A (250 Hz) - 52A (500 Hz) 53A (250 Hz) - 222 (1.8 kHz) - CW RTTY - 52A (500 Hz) 53A (250 Hz) - 222 (1.8 kHz) - i Push [PWR] for 1 sec. to exit initial set mode. NOR (2.4 kHz) NOR (2.4 kHz) NOR (2.4 kHz) NOR (2.4 kHz) NOR (2.4 kHz) NOR (2.4 kHz) AM 52A (500 Hz) 53A (250 Hz) 96 (2.8 kHz) 222 (1.8 kHz) 257 (3.3 kHz) : default 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

22
4
OPERATION
When an optional filter is installed, set the optional fil-
ters in
initial set mode
. Optional filters are not se-
lected by default. (p. 33)
D
Optional filter setting
q
While pushing and holding [SET], push [PWR] to
enter
initial set mode
.
w
Push [UP
Y
] or [
Z
DN] several times until “FIL” ap-
pears on the display.
e
Rotate the channel selector to select the installed
filter.
• “no,” “52A,” “53A,” “96,” “222” and “257” indicate no op-
tional filter, FL-52A, FL-53A, FL-96, FL-222 and
FL-257, respectively for 455 kHz IF filter selection.
r
Push [PWR] for 1 sec. to exit
initial set mode
.
D
Expanded filter selection
The selectable filter combinations can be expanded
by setting the expanded filter selection to ON. Then
extra wide or narrow filter can be selected on desired
mode.
q
While pushing and holding [SET], push [PWR] to
enter
initial set mode
.
w
Push [UP
Y
] or [
Z
DN] several times until “EXP
FIL” appears.
e
Rotate the channel selector to turn the expanded
filter selection ‘on’.
• If ‘on’ is selected, the expanded filter selection can be
used.
Wide/narrow filter selection
r
Push [UP
Y
] several times until
“WIDE
” or “NAR
” appears
on the display.
t
Push [MODE] several times to se-
lect the desired mode.
y
Rotate the channel selector to se-
lect a filter.
u
Repeat steps
t
and
y
to select
IF filters for other modes, if de-
sired.
•The filter combinations are stored
depending on operating modes.
i
Push [PWR] for 1 sec. to exit
ini-
tial set mode
.
Filter setting
Narrow filter setting table
Wide filter setting table
no
FL-52A
FL-53A
FL-96
FL-222
FL-257
SSB
no
no
no
96 (2.8 kHz)
no
257 (3.3 kHz)
THU (6 kHz)
THU (6 kHz)
THU (6 kHz)
THU (6 kHz)
THU (6 kHz)
THU (6 kHz)
CW
no
no
no
96 (2.8 kHz)
no
257 (3.3 kHz)
THU (6 kHz)
THU (6 kHz)
THU (6 kHz)
THU (6 kHz)
THU (6 kHz)
THU (6 kHz)
RTTY
no
no
no
96 (2.8 kHz)
no
257 (3.3 kHz)
THU (6 kHz)
THU (6 kHz)
THU (6 kHz)
THU (6 kHz)
THU (6 kHz)
THU (6 kHz)
AM
: default
no
FL-52A
FL-53A
FL-96
FL-222
FL-257
SSB
no
no
222 (1.8 kHz)
52A (500 Hz) 53A (250 Hz)
CW
52A (500 Hz)
53A (250 Hz)
222 (1.8 kHz)
RTTY
52A (500 Hz)
53A (250 Hz)
222 (1.8 kHz)
AM
NOR (2.4 kHz)
NOR (2.4 kHz)
NOR (2.4 kHz)
NOR (2.4 kHz)
NOR (2.4 kHz)
NOR (2.4 kHz)
52A (500 Hz)
53A (250 Hz)
96 (2.8 kHz)
222 (1.8 kHz)
257 (3.3 kHz)