JVC DT-V1710CGU Instruction Manual - Page 23

How To Use External, Control

Page 23 highlights

HOW TO USE EXTERNAL CONTROL Ⅵ ABOUT EXTERNAL CONTROL The Multi-Format Monitor has two external control terminals. One is the MAKE/TRIGGER terminal, which allows the monitor to be controlled by the MAKE(make contact) or TRG. (trigger contact) method selected in the function setting. MAKE (make contact system): Controls functions either by short-circuiting (short with GND of 15th terminal) or stable disconnection (terminal open) of the controlled terminal. TRG. (trigger system) : Controls the function by instantaneously (one second) short-circuiting (short with GND of 15th terminal) the controlled terminal. * MAKE or TRIGGER are selected from REMOTE SYSTEM in the setup menu. The other terminal used for remote control is the RS-485 terminal, and this allows the monitor to be controlled by serial communication. NOTE: Control priority is in the following order; 1 MAKE/TRIGGER terminal > 2RS-485 terminal > 3 front panel buttons. When trigger contact is on, the front panel buttons can be operated. Ⅵ HOW TO USE THE MAKE/TRIGGER TERMINAL 10 9 8 54321 76 15 14 13 12 11 No. Functions to be controlled 1 Turns on the tally lamp 2 Changes the input to INPUT A 3 Changes the input to INPUT B 4 Changes the input to INPUT C 5 Changes the input to INPUT D 6 Changes the input to INPUT E 7 Changes the input to INPUT F 8 COLOR OFF 9 AREA MARKER 10 ASPECT 11 TALLY SELECT 12 AREA MARKER set-up 13 STATUS DISPLAY 14 External Control 15 GND Disconnection Short-circuiting *1 Off On *2 Invalid Valid Invalid Valid Invalid Valid Invalid Valid Invalid Valid Invalid Valid Off On Off On Off On GREEN RED without "R-" with "R-" *3 ON OFF Invalid Valid *2 *1 : The TRIGGER (trigger contact) system switches each setting by instantaneously (approx. 1 second) short-circuiting (short with GND of 15th terminal) the controlled terminal. *2 : TALLY (1st terminal) and EXTERNAL CONTROL (14th terminal) must be controlled with the MAKE (make contact) system even under the TRIGGER (trigger contact) system. *3 : Activating each with "R-" or without "R-" setting in the AREA MARKER menu is possible. Refer to "AREA MARKER" on page 16 for details. Operation 1. Short-circuit EXTERNAL CONTROL (14th terminal) to GND (15th terminal) to activate the external control. 2. Under the MAKE system, controls each function by short-circuiting (short with GND of 15th terminal) or stable disconnection (terminal open) of the controlled terminal. 3. Under the TRIGGER (trigger contact) system, controls each function by Pulse Control, that is by instantaneously (approx. 1 second) short-circuiting (short with GND of 15th terminal) the controlled terminal. NOTES: • When using INPUT A (the 2nd pin) through INPUT F (7th terminal), only the terminal in use should be short-circuited, the others must be disconnected. • Under the TRIGGER system, multiple terminals cannot be short-circuited to GND (15th terminal). Be sure to short-circuit the single terminal to GND. 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

23
HOW TO USE EXTERNAL
CONTROL
±
ABOUT EXTERNAL CONTROL
The Multi-Format Monitor has two external control terminals.
One is the MAKE/TRIGGER terminal, which allows the monitor to be controlled by the MAKE(make contact) or TRG. (trigger
contact) method selected in the function setting.
MAKE (make contact system): Controls functions either by short-circuiting (short with GND of 15th terminal) or stable disconnec-
tion (terminal open) of the controlled terminal.
TRG. (trigger system)
: Controls the function by instantaneously (one second) short-circuiting (short with GND of 15th
terminal) the controlled terminal.
* MAKE or TRIGGER are selected from REMOTE SYSTEM in the setup menu.
The other terminal used for remote control is the RS-485 terminal, and this allows the monitor to be controlled by serial
communication.
NOTE:
Control priority is in the following order;
1
MAKE/TRIGGER terminal >
2
RS-485 terminal >
3
front panel buttons.
When trigger contact is on, the front panel buttons can be operated.
10
9
8
54321
7
6
14
15
13
12
11
*
1 : The TRIGGER (trigger contact) system switches each setting by instantaneously (approx. 1 second) short-circuiting (short with GND of 15th terminal) the
controlled terminal.
*2 : TALLY (1st terminal) and EXTERNAL CONTROL (14th terminal) must be controlled with the MAKE (make contact) system even under the TRIGGER (trigger
contact) system.
*3 : Activating each with “R-” or without “R-” setting in the AREA MARKER menu is possible. Refer to “AREA MARKER” on page 16 for details.
Operation
1. Short-circuit EXTERNAL CONTROL (14th terminal) to GND (15th terminal) to activate the external control.
2. Under the MAKE system, controls each function by short-circuiting (short with GND of 15th terminal) or stable disconnection
(terminal open) of the controlled terminal.
3. Under the TRIGGER (trigger contact) system, controls each function by Pulse Control, that is by instantaneously (approx. 1
second) short-circuiting (short with GND of 15th terminal) the controlled terminal.
NOTES:
• When using INPUT A (the 2nd pin) through INPUT F (7th terminal), only the terminal in use should be short-circuited, the others must be
disconnected.
• Under the TRIGGER system, multiple terminals cannot be short-circuited to GND (15th terminal). Be sure to short-circuit the single terminal to
GND.
No.
Functions to be controlled
Disconnection
Short-circuiting
*1
1
Turns on the tally lamp
Off
On
*2
2
Changes the input to INPUT A
Invalid
Valid
3
Changes the input to INPUT B
Invalid
Valid
4
Changes the input to INPUT C
Invalid
Valid
5
Changes the input to INPUT D
Invalid
Valid
6
Changes the input to INPUT E
Invalid
Valid
7
Changes the input to INPUT F
Invalid
Valid
8
COLOR OFF
Off
On
9
AREA MARKER
Off
On
10
ASPECT
Off
On
11
TALLY SELECT
GREEN
RED
12
AREA MARKER set-up
without “R-”
with “R-”
*3
13
STATUS DISPLAY
ON
OFF
14
External Control
Invalid
Valid
*2
15
GND
±
HOW TO USE THE MAKE/TRIGGER TERMINAL