JVC DT-V1710CGU Instruction Manual - Page 24

How To Use The Rs-485 Terminal - specifications

Page 24 highlights

HOW TO USE EXTERNAL CONTROL (cont'd) Ⅵ HOW TO USE THE RS-485 TERMINAL You can control the monitor from the controller (exclusive for this monitor) or your PC via the RS-485 terminal. For details on operating the monitor from the PC, consult the service center. 1. Cable Prepare a straight cable with a D-sub connector (9-pin, male) and a D-sub connector (9-pin, male) 5 9 4 8 7 3 2 6 1 2. Communications Specifications Baud Rate : 4800/9600/19200 (factory pre-set; 4800) Data Bits : 8 bits Parity : No parity Stop Bits :1 Communication Cord : ASCII Cord 3. Commands Format Pin No. 1 2 3 4 IN terminal signal 5V Power (for controller exclusively for this monitor) TD+ RD+ NC OUT terminal signal NC TD+ RD+ NC Header ID Command ID Command Content Data CR Header ! Control from the PC to the monitor ? Reference from the PC to the monitor @ Answer from the monitor to the PC ID + Command + Data 5 NC NC 6 NC NC 7 TD- TD- 8 RD- RD- 9 NC NC * The 5V power supply of the 1st terminal is for the controller exclusively for this monitor. Do not use it for other devices. B Basic command Characters 00, 01 or No data D Command for adjusting the picture size 00 ~ 08 U, D (U: UP, D: DOWN) S Command for adjusting the picture quality 00 ~ 05 U, D (U: UP, D: DOWN) M Command for selecting the menu item 00 ~ 0E 00, 01, 10, 11 F Command for selecting the menu item 00 ~ 10 00, 01, 02, 03, 04, 05 W Command for adjusting the white balance 00 ~ 05 U, D (U: UP, D: DOWN) C Command for inquiring for the monitor's status 00 0 ~ 655 Communication Procedures The following is the communication procedures. 1. Starting the communication Receives the connection command (!XXBCN1Cr) from the PC [ Sends the monitor's status (@XXBOKCr) to the PC 2. Performing the external control Receives the control command (!XXXXCr) from the PC [ Sends the monitor's status (@XXBOKCr) to the PC * The monitor repeats these receiving and sending if necessary. 3. Terminating the communication Receives the termination command (!XXBCN0Cr) [ Sends the monitor's status (@XXBOKCr) to the PC * Hand-shake communication is used. This means that after sending a command to the monitor, the PC must receive a status return from the monitor before sending the next command. * When the monitor is controlled by a PC via RS-485, a conversion adapter (RS-232Cp[RS-485) is also required. 24

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

24
±
HOW TO USE THE RS-485 TERMINAL
You can control the monitor from the controller (exclusive for this monitor) or your PC via the RS-485 terminal.
For details on
operating the monitor from the PC, consult the service center.
1. Cable
Prepare a straight cable with a D-sub connector (9-pin, male) and a D-sub
connector (9-pin, male)
2. Communications Specifications
Baud Rate
: 4800/9600/19200 (factory pre-set; 4800)
Data Bits
: 8 bits
Parity
: No parity
Stop Bits
:1
Communication Cord :
ASCII Cord
3. Commands
Format
Header
ID
Command ID
Command Content
Data
CR
Header
!
Control from the PC to the monitor
?
Reference from the PC to the monitor
@
Answer from the monitor to the PC
ID
+
Command + Data
B
Basic command
Characters
00, 01 or No data
D
Command for adjusting the picture size
00 ~ 08
U, D (U: UP, D: DOWN)
S
Command for adjusting the picture quality
00 ~ 05
U, D (U: UP, D: DOWN)
M
Command for selecting the menu item
00 ~ 0E
00, 01, 10, 11
F
Command for selecting the menu item
00 ~ 10
00, 01, 02, 03, 04, 05
W
Command for adjusting the white balance
00 ~ 05
U, D (U: UP, D: DOWN)
C
Command for inquiring for the monitor
s status
00
0 ~ 655
Communication Procedures
The following is the communication procedures.
1. Starting the communication
Receives the connection command (!XXBCN1Cr) from the PC
[
Sends the monitor
s status (@XXBOKCr) to the PC
2. Performing the external control
Receives the control command (!XXXXCr) from the PC
[
Sends the monitor
s status (@XXBOKCr) to the PC
* The monitor repeats these receiving and sending if necessary.
3. Terminating the communication
Receives the termination command (!XXBCN0Cr)
[
Sends the monitor
s status (@XXBOKCr) to the PC
* Hand-shake communication is used. This means that after sending a command to the monitor, the PC must receive a status
return from the monitor before sending the next command.
* When the monitor is controlled by a PC via RS-485, a conversion adapter (RS-232C
p[
RS-485) is also required.
4
3
2
1
9
8
5
7
6
Pin No.
IN terminal
OUT terminal
signal
signal
1
5V Power (for
controller exclusively
NC
for this monitor)
2
TD
+
TD
+
3
RD
+
RD
+
4
NC
NC
5
NC
NC
6
NC
NC
7
TD
TD
8
RD
RD
9
NC
NC
* The 5V power supply of the 1st terminal is for the controller
exclusively for this monitor.
Do not use it for other devices.
HOW TO USE EXTERNAL
CONTROL
(cont'd)