LG 32LD655H Setup Guide - Page 36

Reference: Power Consumption Settings

Page 36 highlights

Reference: Power Consumption Settings 32/37/42LD650H/LD655H The following tables assume that Installer Menu item 118 POWER SAVINGS is set to 003 (default) and Installer Menu item 099 BACK LIGHTING is set as shown below (default value is 255). 32LD650H/ LD655H Item 099 Back Lighting (Static) 100 90 80 70 60 50 40 30 20 10 1 Picture Lumin. 290.2 258.2 220.2 189.1 166.6 145.2 126.4 108.2 90.2 72.1 57.5 Power Consumption (Watts) 96.1 90.9 84.8 80.2 75.5 69.1 63.9 58.8 53.2 48.6 44.0 Percent Savings 0.00% 5.41% 11.76% 16.55% 21.44% 28.10% 33.51% 38.81% 44.64% 49.43% 54.21% Item 099 Back Lighting (Dynamic) 202 200 190 180 170 160 150 140 130 120 110 Picture Lumin. 105.1 85.5 80.0 75.7 70.6 67.1 63.2 60.0 56.6 52.5 49.2 Power Consumption (Watts) 56.1 51.5 50.5 49.7 48.6 48.0 47.1 46.3 45.7 44.7 44.1 Percent Savings 41.62% 46.41% 47.45% 48.28% 49.43% 50.05% 50.99% 51.82% 52.45% 53.49% 54.11% 37LD650H/ LD655H Item 099 Back Lighting (Static) 100 90 80 70 60 50 40 30 20 10 1 Picture Lumin. 193.5 178.5 163.1 149.0 134.6 118.9 104.1 89.1 72.6 57.1 41.5 Power Consumption (Watts) 113.4 106.5 100.1 93.8 88.0 81.5 75.2 69.2 62.5 56.1 49.7 Percent Savings 0.00% 6.08% 11.73% 17.28% 22.40% 28.13% 33.69% 38.98% 44.89% 50.53% 56.17% Item 099 Back Lighting (Dynamic) 202 200 190 180 170 160 150 140 130 120 110 Picture Lumin. 116.4 94.1 88.6 83.1 77.5 71.9 67.1 61.4 55.8 50.2 44.3 Power Consumption (Watts) 82.7 72.1 70.1 67.7 65.3 63.0 61.3 59.0 56.4 54.1 51.8 Percent Savings 27.07% 36.42% 38.18% 40.30% 42.42% 44.44% 45.94% 47.97% 50.26% 52.29% 54.32% 42LD650H/ LD655H 36 Item 099 Back Lighting (Static) 100 90 80 70 60 50 40 30 20 10 1 Picture Lumin. 212.8 195.8 177.9 160.0 143.7 124.7 107.6 90.8 72.6 55.3 39.4 Power Consumption (Watts) 144.1 135.0 125.7 117.5 109.1 100.1 91.8 83.4 74.2 65.7 57.5 Percent Savings 0.00% 6.32% 12.77% 18.46% 24.29% 30.53% 36.29% 42.12% 48.51% 54.41% 60.10% Item 099 Back Lighting (Dynamic) 202 200 190 180 170 160 150 140 130 120 110 Picture Lumin. 109.8 90.1 84.2 78.6 72.5 66.6 62.2 56.3 50.7 45.1 39.5 Note: Values are results of controlled experiments under laboratory conditions. Power Consumption (Watts) 98.2 85.8 82.8 79.7 76.6 73.6 71.2 68.2 65.2 62.1 59.8 Percent Savings 31.85% 40.46% 42.54% 44.69% 46.84% 48.92% 50.59% 52.67% 54.75% 56.90% 58.50% 206-4137

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

36
206-4137
Reference: Power Consumption Settings
32/37/42LD650H/LD655H
The following tables assume that Installer Menu item 118 POWER SAVINGS is set to 003 (default) and
Installer Menu item 099 BACK LIGHTING is set as shown below (default value is 255).
32LD650H/
LD655H
Note: Values are results of controlled experiments under laboratory conditions.
37LD650H/
LD655H
42LD650H/
LD655H
Item 099
Back Lighting
(Static)
Picture
Lumin.
Power
Consumption
(Watts)
Percent
Savings
Item 099
Back Lighting
(Dynamic)
Picture
Lumin.
Power
Consumption
(Watts)
Percent
Savings
100
290.2
96.1
0.00%
202
105.1
56.1
41.62%
90
258.2
90.9
5.41%
200
85.5
51.5
46.41%
80
220.2
84.8
11.76%
190
80.0
50.5
47.45%
70
189.1
80.2
16.55%
180
75.7
49.7
48.28%
60
166.6
75.5
21.44%
170
70.6
48.6
49.43%
50
145.2
69.1
28.10%
160
67.1
48.0
50.05%
40
126.4
63.9
33.51%
150
63.2
47.1
50.99%
30
108.2
58.8
38.81%
140
60.0
46.3
51.82%
20
90.2
53.2
44.64%
130
56.6
45.7
52.45%
10
72.1
48.6
49.43%
120
52.5
44.7
53.49%
1
57.5
44.0
54.21%
110
49.2
44.1
54.11%
Item 099
Back Lighting
(Static)
Picture
Lumin.
Power
Consumption
(Watts)
Percent
Savings
Item 099
Back Lighting
(Dynamic)
Picture
Lumin.
Power
Consumption
(Watts)
Percent
Savings
100
193.5
113.4
0.00%
202
116.4
82.7
27.07%
90
178.5
106.5
6.08%
200
94.1
72.1
36.42%
80
163.1
100.1
11.73%
190
88.6
70.1
38.18%
70
149.0
93.8
17.28%
180
83.1
67.7
40.30%
60
134.6
88.0
22.40%
170
77.5
65.3
42.42%
50
118.9
81.5
28.13%
160
71.9
63.0
44.44%
40
104.1
75.2
33.69%
150
67.1
61.3
45.94%
30
89.1
69.2
38.98%
140
61.4
59.0
47.97%
20
72.6
62.5
44.89%
130
55.8
56.4
50.26%
10
57.1
56.1
50.53%
120
50.2
54.1
52.29%
1
41.5
49.7
56.17%
110
44.3
51.8
54.32%
Item 099
Back Lighting
(Static)
Picture
Lumin.
Power
Consumption
(Watts)
Percent
Savings
Item 099
Back Lighting
(Dynamic)
Picture
Lumin.
Power
Consumption
(Watts)
Percent
Savings
100
212.8
144.1
0.00%
202
109.8
98.2
31.85%
90
195.8
135.0
6.32%
200
90.1
85.8
40.46%
80
177.9
125.7
12.77%
190
84.2
82.8
42.54%
70
160.0
117.5
18.46%
180
78.6
79.7
44.69%
60
143.7
109.1
24.29%
170
72.5
76.6
46.84%
50
124.7
100.1
30.53%
160
66.6
73.6
48.92%
40
107.6
91.8
36.29%
150
62.2
71.2
50.59%
30
90.8
83.4
42.12%
140
56.3
68.2
52.67%
20
72.6
74.2
48.51%
130
50.7
65.2
54.75%
10
55.3
65.7
54.41%
120
45.1
62.1
56.90%
1
39.4
57.5
60.10%
110
39.5
59.8
58.50%