LG LMU240HE Service Manual - Page 25
Indoor unit installation
View all LG LMU240HE manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Wrap the insulation material around the connecting portion. 1. Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there may be no gap. 2. Wrap the area which accommodates the rear piping housing section with vinyl tape. 3. Bundle the piping and drain hose together by wrapping them with cloth tape over the range within which they fit into the rear piping housing section. Reroute the pipings and the drain hose across the back of the chassis. Flaring Work and Connection of Piping Plastic bands Insulation material Connection pipe Vinyl tape (wide) Connecting cable Wrap with vinyl tape Pipe Indoor unit piping Vinyl tape(narrow) Drain hose Pipe Vinyl tape(narrow) Wrap with vinyl tape(wide) Indoor unit installation 1. Remove the spacer. 2. Ensure that the hooks are properly seated on the installation plate by moving it left and right. 3. Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound). Piping for passage through piping hole Connecting cable Drain hose Service Manual 25