LG LMU240HE Service Manual - Page 73
Check Point
View all LG LMU240HE manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
Error code Title 05 / 53 Communication (Indoor ➔ Outdoor) Troubleshooting Guide Cause of error Check point & Normal condition • Power input AC 230V.(Outdoor, Indoor) • The connector for transmission is disconnected. • The connecting wires are misconnected. • Communication poorly • The GND 1,2 is not connected at main GND. • The communication line is shorted at GND. • Transmission circuit of outdoor PCB is abnormal. • Transmission circuit of indoor PCB is abnormal. ❑ Check Point 1. Check the input power AC 230V.(Outdoor, Indoor) 2. Check the communication wires are correctly connected. ➔ Adjust the connection of wire ➔ Confirm the wire of "Live", "Neutral". 3. Check the resistance between communication line and GND.(Normal : Over 2MΩ) 4. Check the connector for communication is correctly connected. 5. Check the connection of GND1, GND2, and main GND. 6. If one indoor unit is operated normally, outdoor PCB is no problem. ➔ Check the another indoor unit. * CH05 is displayed at indoor unit, CH53 is displayed at outdoor unit. Service Manual 73