LG LSC121PMA Service Manual - Page 23
Connection of the pipes-Outdoor
View all LG LSC121PMA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
CAUTION Installation Information (For right piping) • Good case For right piping, follow the instruction below. s Press on the upper side of clamp and unfold the tubing to downward slowly. 3) Connection of the pipes-Outdoor 1. Align the center of the pipings and sufficiently tighten the flare nut by hand. s Bend the tubing to the right side of chassis. 2. Finally, tighten the flare nut with torque wrench until the wrench clicks. s When tightening the flare nut with torque wrench, ensure the direction for tightening follows the arrow on the wrench. Capacity (Btu/h) 9K 12K Pipe Size[Torque] GAS LIQUID 1/2"[5.5kg.m] 1/4"[1.8kg.m] 1/2"[5.5kg.m] 1/4"[1.8kg.m] • Bad case s Following bending type from right to left could cause problem of pipe damage. OOuuttddoooorr uunniitt Outdoor unit GLiaqsuisdidseidpeippinipging L(S((iBqSmuimgaidglaleselrilrdededriaipadmimipaeinetmegtree)rt)er) GasGsiadse side pLipiqinupgiidpisnigde (dp(BiSaiipgmmi(dgnBeaeigatlirelgmerg)reetrer) diameter) Torque wrench Torque wrench Torque wrench -23-