LG LSC121PMA Service Manual - Page 26
checking the Drainage and forming the pipings
View all LG LSC121PMA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
4. checking the Drainage and forming the pipings 1) Checking the drainage 1. To check the drainage. s Pour a glass of water on the evaporator. s Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit. 2) Form the piping 1. Form the piping by wrapping the connecting portion of the indoor unit with insulation material and secure it with two kinds of vinyl tapes. s If you want to connect an additional drain hose, the end of the drain outlet should be routed above the ground. Secure the drain hose appropriately. 2. In cases where the outdoor unit is installed below the indoor unit perform the following. s Tape the piping, drain hose and connecting cable from down to up. s Secure the tapped piping along the exterior wall using saddle or equivalent. Seal small openings around pipings with a gum type sealer. Taping Drain hose Pipings Connecting cable 2. Drain piping s The drain hose should point downward for easy drain flow. Downward slope s Do not make drain piping. Do not raise Accumulated drain water Air Tip of drain hose dipped in water Water leakage Water leakage Waving Water leakage Ditch Less than 50mm gap Trap is required to prevent water from entering into electrical parts. 3. In cases where the Outdoor unit is installed above the Indoor unit perform the following. s Tape the piping and connecting cable from down to up. s Secure the taped piping along the exterior wall. Form a trap to prevent water entering the room. s Fix the piping onto the wall by saddle or equivalent. Seal a small opening around the pipings with gum type sealer. Trap Trap -26-