LG WT5101HW Owner's Manual - Page 9
Installation Instructions - 27
View all LG WT5101HW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
INSTALLATION INSTRUCTIONS ENGLISH CHOOSE THE PROPER LOCATION wWARNING • The washer is heavy! Two or more people are required when moving and unpacking the washer. Failure to do so can result in back or other injury. •Store and install the washer where it will not be exposed to temperatures below freezing or exposed to outdoor weather conditions. Failure to follow this warning can cause serious injury, fire, electrical shock, or death. • Properly ground washer to conform with all governing codes and ordinances. Failure to follow this warning can cause serious injury, fire, electrical shock, or death. • T o reduce the risk of electric shock, do not install the washer in humid spaces. Failure to follow this warning can cause serious injury, fire, electrical shock, or death. • The base opening must not be obstructed by carpeting when the washer is installed on a carpeted floor. • Keep the area underneath and around your appliances free of combustible materials such as lint, paper, rags, chemicals, etc. • Do not remove ground prong. Do not use an adapter or extension cord. Plug into a grounded 3-prong outlet. Failure to follow this warning can cause serious injury, fire, electrical shock, or death. POWER OUTLET • The power outlet must be within 60 inches (1.5 m) of either side of the washer. • The appliance and outlet must be positioned so that the plug is easily accessible. • Do not overload the outlet with more than one appliance. • The outlet must be grounded in accordance with current wiring codes and regulations. • Time-delay fuse or circuit breaker is recommended. NOTE: It is the personal responsibility and obligation of the product owner to have a proper outlet installed by a qualified electrician. FLOORING • To minimize noise and vibration, the washer MUST be installed on a solidly constructed floor. • Allowable slope under the entire washer is 1° maximum. • Carpeting and soft tile surfaces are not recommended. • Never install the washer on a platform or weakly supported structure. NOTE: The washer must be installed on firm flooring to minimize vibration during the spin cycle. Concrete flooring is best, but a wood floor is sufficient, provided it is built to FHA standards. The washer should not be installed on rugs or exposed to weather. CLEARANCES 453/8″ (115.3 cm) 453/8″ (115.3 cm) 1″ (2.5 cm) 27″ (68.6 cm) 1″ (2.5 cm) Taolloewnsmuirne(im2s.u5u1fm″fcimcic)elneat rcalen(6ac8re2a.s67n″cocmfea)ftorlewasa(t2te.15r1″ilcninmceh)ses (2.5 cm) at the sides and 4 inches (10 cm) behind the unit. Be sure to allow for wall, lid, or floor moldings that may increase the required clearances. 55.3/4″ (141.7 cm) (woipth(e1nl54i)d51..37/4c″m) (with lid open) 28.3/8″ (72.1 cm) 28.3/8″ (72.1 cm) 4″ (10 cm) 4″ (10 cm) Minimum vertical space from floor to overhead shelves, cabinets, ceilings, etc., is 56". 9