Lenovo ThinkCentre M57 Hardware Maintenance Manual - Page 54

XX-XXX 005-3XX-XXX, Diskette drive Cable

Page 54 highlights

Diagnostic Error Code 005-031-XXX Video Device Cable failure 005-032-XXX Video Device Controller failure 005-036-XXX Video Register error 005-038-XXX System BIOS extension failure 005-040-XXX Video IRQ failure 005-195-XXX Video Test aborted by user 005-196-XXX Video test halt, error threshold exceeded 005-197-XXX Video test warning 005-198-XXX Video test aborted 005-199-XXX Video test failed, cause unknown 005-2XX-XXX 005-3XX-XXX Video subsystem error 006-000-XXX Diskette interface Test Passed 006-0XX-XXX Diskette interface error 006-195-XXX Diskette interface Test aborted by user 006-196-XXX Diskette interface test halt, error threshold exceeded FRU/Action 1. Video cable 2. Monitor 3. Video card, if installed 4. System board 1. Video card, if installed 2. System board 1. Video card, if installed 2. System board 1. Video card, if installed 2. System board 1. Video card, if installed 2. System board Information only Re-start the test, if necessary 1. Press F3 to review the log file 2. Re-start the test to reset the log file 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6 "Diagnostics, Test and Recovery Information" on page 39 2. Re-run test 3. Replace the component called out in warning statement 4. Replace the component under test 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6 "Diagnostics, Test and Recovery Information" on page 39 2. Flash the system and re-test. See "Updating (flashing) BIOS from a CD-ROM or diskette" on page 139 3. Go to "Undetermined problems" on page 62 1. Go to "Undetermined problems" on page 62 2. Flash the system and re-test. See "Updating (flashing) BIOS from a CD-ROM or diskette" on page 139 3. Replace component under function test 1. Video card, if installed 2. System board No action 1. Diskette drive Cable 2. Diskette drive 3. System board Information only Re-start the test, if necessary 1. Press F3 to review the log file 2. Re-start the test to reset the log file 48 Hardware Maintenance Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152

Diagnostic Error Code
FRU/Action
005-031-XXX
Video Device Cable failure
1.
Video cable
2.
Monitor
3.
Video card, if installed
4.
System board
005-032-XXX
Video Device Controller failure
1.
Video card, if installed
2.
System board
005-036-XXX
Video Register error
1.
Video card, if installed
2.
System board
005-038-XXX
System BIOS extension failure
1.
Video card, if installed
2.
System board
005-040-XXX
Video IRQ failure
1.
Video card, if installed
2.
System board
005-195-XXX
Video Test aborted by user
Information only
Re-start the test, if necessary
005-196-XXX
Video test halt, error threshold exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
005-197-XXX
Video test warning
1.
Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 39
2.
Re-run test
3.
Replace the component called out in warning
statement
4.
Replace the component under test
005-198-XXX
Video test aborted
1.
If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 39
2.
Flash the system and re-test. See “Updating (flashing)
BIOS from a CD-ROM or diskette” on page 139
3.
Go to “Undetermined problems” on page 62
005-199-XXX
Video test failed, cause unknown
1.
Go to “Undetermined problems” on page 62
2.
Flash the system and re-test. See “Updating (flashing)
BIOS from a CD-ROM or diskette” on page 139
3.
Replace component under function test
005-2XX-XXX 005-3XX-XXX
Video subsystem error
1.
Video card, if installed
2.
System board
006-000-XXX
Diskette interface Test Passed
No action
006-0XX-XXX
Diskette interface error
1.
Diskette drive Cable
2.
Diskette drive
3.
System board
006-195-XXX
Diskette interface Test aborted by user
Information only
Re-start the test, if necessary
006-196-XXX
Diskette interface test halt, error threshold
exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
48
Hardware Maintenance Manual