Lenovo ThinkCentre M57 Hardware Maintenance Manual - Page 59

RAID interface Test Passed, RAID interface Failure

Page 59 highlights

Diagnostic Error Code 030-195-XXX SCSI interface Test aborted by user 030-196-XXX SCSI interface test halt, error threshold exceeded 030-197-XXX SCSI interface test warning 030-198-XXX SCSI interface test aborted 030-199-XXX SCSI interface test failed, cause unknown 035-000-XXX RAID interface Test Passed 035-0XX-XXX RAID interface Failure 035-195-XXX RAID interface Test aborted by user 035-196-XXX RAID interface test halt, error threshold exceeded 035-197-XXX RAID interface test warning 035-198-XXX RAID interface test aborted FRU/Action Information only Re-start the test, if necessary 1. Press F3 to review the log file 2. Re-start the test to reset the log file 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6 "Diagnostics, Test and Recovery Information" on page 39 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6 "Diagnostics, Test and Recovery Information" on page 39 2. Flash the system and re-test. See "Updating (flashing) BIOS from a CD-ROM or diskette" on page 139 3. Go to "Undetermined problems" on page 62 1. Go to "Undetermined problems" on page 62 2. Flash the system and re-test. See "Updating (flashing) BIOS from a CD-ROM or diskette" on page 139 3. Replace component under function test No action 1. RAID signal cable 2. RAID device 3. RAID adapter card, if installed 4. System board Information only Re-start the test, if necessary 1. Press F3 to review the log file 2. Re-start the test to reset the log file 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6 "Diagnostics, Test and Recovery Information" on page 39 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6 "Diagnostics, Test and Recovery Information" on page 39 2. Flash the system and re-test. See "Updating (flashing) BIOS from a CD-ROM or diskette" on page 139 3. Go to "Undetermined problems" on page 62 Chapter 7. Symptom-to-FRU Index 53

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152

Diagnostic Error Code
FRU/Action
030-195-XXX
SCSI interface Test aborted by user
Information only
Re-start the test, if necessary
030-196-XXX
SCSI interface test halt, error threshold
exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
030-197-XXX
SCSI interface test warning
1.
Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 39
2.
Re-run test
3.
Replace the component that is called out in warning
statement
4.
Replace the component under test
030-198-XXX
SCSI interface test aborted
1.
If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 39
2.
Flash the system and re-test. See “Updating (flashing)
BIOS from a CD-ROM or diskette” on page 139
3.
Go to “Undetermined problems” on page 62
030-199-XXX
SCSI interface test failed, cause unknown
1.
Go to “Undetermined problems” on page 62
2.
Flash the system and re-test. See “Updating (flashing)
BIOS from a CD-ROM or diskette” on page 139
3.
Replace component under function test
035-000-XXX
RAID interface Test Passed
No action
035-0XX-XXX
RAID interface Failure
1.
RAID signal cable
2.
RAID device
3.
RAID adapter card, if installed
4.
System board
035-195-XXX
RAID interface Test aborted by user
Information only
Re-start the test, if necessary
035-196-XXX
RAID interface test halt, error threshold
exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
035-197-XXX
RAID interface test warning
1.
Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 39
2.
Re-run test
3.
Replace the component that is called out in warning
statement
4.
Replace the component under test
035-198-XXX
RAID interface test aborted
1.
If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 39
2.
Flash the system and re-test. See “Updating (flashing)
BIOS from a CD-ROM or diskette” on page 139
3.
Go to “Undetermined problems” on page 62
Chapter 7
.
Symptom-to-FRU Index
53