Lexmark E120 User's Guide - Page 18

Using the operator panels, Complex ENA connection lost - network setup

Page 18 highlights

Using the operator panels Complex page Light sequence: Error-On Secondary light sequence: Press twice quickly to see the secondary light sequence. Ready / Data-Blinks three times Message: The page may not print correctly because the print information on the page is too complex (that is, too large for printer memory). Primary light sequence Secondary light sequence Solution: Turn printer off and back on to try printing the page again. If not successful: • Press to clear message and continue processing the job (some print data may be lost). To avoid this error in the future: • Reduce complexity of the page by reducing the amount of text or graphics. • Set Page Protect to On in the Local Printer Setup Utility (see Software and Documentation CD). ENA connection lost Light sequence: Error-On Secondary light sequence: Press twice quickly to see the secondary light sequence. Ready / Data-Blinks five times Message: During power-on cycle, the printer detected the connection to the external network adapter was lost. Primary light sequence Note: This error is only detected during the power-on cycle. Solution: • Press to clear message. • Re-establish connection with the external network adapter. Secondary light sequence Overview of the Lexmark E120 operator panel 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87

Overview of the Lexmark E120 operator panel
18
Using the operator panels
Complex page
ENA connection lost
Light sequence:
Error—On
Secondary light sequence:
Press
twice quickly to see the secondary light
sequence.
Ready / Data—Blinks three times
Message:
The page may not print correctly because the print information
on the page is too complex (that is, too large for printer memory).
Solution:
Turn printer off and back on to try printing the page again. If not successful:
Press
to clear message and continue processing the job (some print data may be lost).
To avoid this error in the future:
Reduce complexity of the page by reducing the amount of text or graphics.
Set
Page Protect
to On in the Local Printer Setup Utility (see
Software and Documentation
CD
).
Light sequence:
Error—On
Secondary light sequence:
Press
twice quickly to see the secondary light
sequence.
Ready / Data—Blinks five times
Message:
During power-on cycle, the printer detected the connection to
the external network adapter was lost.
Note:
This error is only detected during the power-on cycle.
Solution:
Press
to clear message.
Re-establish connection with the external network adapter.
Primary light
sequence
Secondary light
sequence
Primary light
sequence
Secondary light
sequence