Service Checks, Cooling Fan Service Check
UPC - 734646183000
View all Lexmark E310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
4044-XXX Service Checks Note: All service checks which involve measuring voltages of the circuit boards (except the controller board) must be performed with the engine/LVPS to controller board cable disconnected and the printer positioned on its left side. This provides the servicer access to the various circuit boards underneath the printer while supplying necessary power to the rest of the printer. Cooling Fan Service Check FRU Model E310 Interconnect Board Cooling Fan Action Make sure motor cable is properly seated in location CN408 on the interconnect board. Disconnect the cable and check connector-pin CN408-3 for +24 V dc. If the voltage is not present, replace the interconnect board. If the voltage is present, replace the cooling fan. FRU Model E312 Engine Board Cooling Fan Action Make sure motor cable is properly seated in location CN3 on the engine board. Disconnect the cable and check connector-pin CN3-1 for +24 V dc. If the voltage is not present, replace the engine board. If the voltage is present, replace the cooling fan. 2-12 Service Manual