Lexmark E310 Service Manual - Page 43
Main Motor Service Check, Hot Fuser Service Check
UPC - 734646183000
View all Lexmark E310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
4044-XXX Hot Fuser Service Check FRU Model E310 Fuser Thermistor Model E312 Fuser Thermistor Models E310 & E312 Fuser Lamp Action Disconnect the thermistor cable from the LVPS. Measure the resistance across CN1-1 and CN1-2 of the thermistor cable. Replace the thermistor if the resistance is lower than 1k ohm or shorted. Disconnect the thermistor cable from the engine board. Measure the resistance across CN10-1 and CN10-3 of the thermistor cable. Replace the thermistor if the resistance is lower than 1k ohm or shorted. Make sure the correct voltage fuser lamp is installed. Replace if necessary. Main Motor Service Check FRU Model E310 Interconnect Board Main Motor Main Motor Cable Action Check the interconnect board for the following voltages: CN405-3 +24 V dc CN405-4 +24 V dc If these voltages are not correct, replace the interconnect board. If these voltages are correct, check the main motor cable for continuity. If continuity exists on each wire, replace the main motor. If continuity does not exist on one or more of the wires, replace the cable. Diagnostic Information 2-21