Lexmark E310 Service Manual - Page 42
Step 2: No Continuity
UPC - 734646183000
View all Lexmark E310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
4044-XXX FRU Model E312 Fuser Lamp Lamp Cable Thermistor LVPS Action Turn the printer off and disconnect the fuser lamp wires from the fuser. Check for continuity across the fuser lamp wire contacts. If there is continuity, go to step 1: Continuity. If there is no continuity, go to step 2: No Continuity. Step 1: Continuity Measure the voltage at connector CN502 on the LVPS. It should match the line voltage. If it does not, replace the LVPS. If line voltage is present, check the fuser lamp cable for continuity. Replace if defective.Make sure the fuser thermistor is correctly connected to CN10 on the engine board. If the problem persists, disconnect the thermistor cable from CN1o on the engine board and measure the voltage between CN10-1 and ground. The voltage measures approximately 3.9 V dc. If the voltage is incorrect, replace the engine board. If correct, replace the thermistor. Step 2: No Continuity Check the thermal fuse for continuity. If incorrect, replace the thermal fuse. If correct, replace the lamp. 2-20 Service Manual