Lexmark Monochrome Laser Administrator's Guide (1.4 MB) - Page 65
Serial Menu, SERIAL OPTION x
View all Lexmark Monochrome Laser manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
Serial Menu NOTE: Serial interface is a standard feature on Optra T612 and T612n printers. SERIAL OPTION x only displays if a Tri-Port interface card is installed. Use the SERIAL MENU to change settings affecting jobs sent to the printer through the serial interface port. The SERIAL MENU only displays when a serial interface port exists on the printer as a standard feature or as an option, and displays as one of the following: • STANDARD SERIAL • SERIAL OPTION x (where x is serial interface connection 1 or 2) Serial Menu Menu item Values PCL SmartSwitch Off On* If PCL SmartSwitch is set to On, the printer examines the data on the serial interface connection and selects PCL emulation if the data indicates that is the printer language. If both PCL SmartSwitch and PS SmartSwitch are set to Off, the printer uses the language specified in the Printer Language menu as the default. If only one SmartSwitch is set to On, the printer uses that language as the default. PS SmartSwitch Off On* If PS SmartSwitch is set to On, the printer examines the data on the serial interface connection and selects PostScript emulation if the data indicates that is the printer language. If both PCL Smartswitch and PS Smartswitch are set to Off, the printer uses the language specified in the Printer Language menu as the default. If only one SmartSwitch is set to On, the printer uses that language as the default. * Factory default Using the Operator Panel and Menus 65