Lexmark Optra S Service Manual - Page 103
Options Service Check, Flash Memory Options - 1250
View all Lexmark Optra S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 103 highlights
4059-XXX FRU 4 Operator Panel all diamonds, No Beeps 5 Operator Panel all diamonds, 5 Beeps Action Check to make sure a SIMM is not plugged in backwards. This condition causes the printer to fail POST displaying all diamonds on the operator panel with no beeps Check the voltage at Pin J11-1 and J11-3. The voltage measures approximately +5 V dc. If incorrect, replace the FRUs in the following order: operator panel assembly engine board Options Service Check Service Tip: When you have a problem with any of the options installed in the options slots on the interconnect board on a 2450 or 1650 (the 1250 has only one slot), switch the non operating option to one of the other option slots to isolate the failure. Flash Memory Option(s) Run a copy of the test page and check to see if the option you are checking is listed. The printer does not recognize the option being installed if the option is not listed. Check to make sure that the Memory SIMM is installed correctly and is not broken or damaged. If the Memory SIMM is correctly installed not broken or damaged then run the "Flash Test" on page 3-3. If the test fails, replace the FLASH SIMM. If the problem continues, replace the controller board. DRAM Memory Option(s) This service check is the same as the flash memory option service check with the following exception: Run the "DRAM Memory Test" on page 3-10 from the menu if the DRAM Memory SIMM is correctly installed and not broken or damaged. If the test fails, replace the DRAM SIMM. If the problem continues, replace the controller board. Diagnostic Information 2-76