Lexmark Optra S Service Manual - Page 197
High Voltage Power Supply, transformer on the HVPS. The cable and connector can
View all Lexmark Optra S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 197 highlights
4059-XXX High Voltage Power Supply 1. Remove the inner paper deflector. 2. Remove the toner sensor cable from the retainer (A) on the front of the HVPS. 3. Remove the right side cover. 4. Disconnect the JVPS cable from the HVPS at connector (C). 5. Disconnect the transfer roll cable from the HVPS board. Note: Use caution when disconnecting the cable from the transformer on the HVPS. The cable and connector can be easily damaged. 6. Remove the HVPS mounting screw (B). 7. Slide the HVPS to the left to release the mounting tab and remove the HVPS. Repair Information 4-34
Repair Information
4-34
4059-XXX
High Voltage Power Supply
1. Remove the inner paper deflector.
2. Remove the toner sensor cable from the retainer (A) on the front
of the HVPS.
3. Remove the right side cover.
4. Disconnect the JVPS cable from the HVPS at connector (C).
5. Disconnect the transfer roll cable from the HVPS board.
Note:
Use caution when disconnecting the cable from the
transformer on the HVPS. The cable and connector can be
easily damaged.
6. Remove the HVPS mounting screw (B).
7. Slide the HVPS to the left to release the mounting tab and
remove the HVPS.