Lexmark Optra S Service Manual - Page 149
Output Bin Sensor Test, Select Sensor Test from the Output Bin Test menu.
View all Lexmark Optra S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 149 highlights
4059-XXX Output Bin Sensor Test This test is used to verify if the output bin sensors are working correctly. To run the Output Bin Sensor Test: 1. Select Sensor Test from the Output Bin Test menu. - "Output Bin/Full=OP/Input=OP" message displays. - Full = Output Bins Full Sensor - Pass = Output Bins Pass Thru Sensor 2. Once the message displays, the servicer can manually actuate each of the output bin sensors. The bin full sensor can be actuated by hand, however a sheet of paper can be used to cover the bin's pass thru sensor. When the sensor is closed CL displays, and when the sensor is open OP displays. 3. Press Return/Stop to exit the test. Output Bin X Sensor Test Note: Some output expanders have a single output bin sensor installed while others have a dual sensor assembly. Both versions have a single pass thru sensor. This test is used to verify if the Output Bin X sensors are working correctly. To run the Output Bin X Sensor tests: 1. Select Output Bin tests from the menu. 2. Select Output Bin tests - Sensor Tests. 3. Select Sensor Tests - Output Bin X. Output Expander with Single Sensor The following is displayed: Output Bin X Full=OP P=OP Full=Bin Full Sensor P=Pass Thru Sensor Diagnostic Aids 3-16