Lexmark Optra S Service Manual - Page 109
Output Expander Control, Board - Level 1 Stepper Motor on, Stepper Motor Level 1
View all Lexmark Optra S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 109 highlights
4059-XXX FRU 3 Stepper Motor Level 1 Action Check the stepper motor connector to ensure it is correctly installed at J4 on the output expander option board. Go to "Output Expander Control Board - Level 1 Stepper Motor" on page 5-22. If correct, disconnect J4 from the option board and check the resistance of the stepper motor at J4: J4-1 to J4-2: Approximately 10 ohms J4-3 to J4-4: Approximately 10 ohms. Also check each winding for shorts between J4-1 thru J4-4 and the motor housing. If you find a problem, replace the stepper motor. If you do not find a problem, replace the output expander mechanical linkage assembly. Diagnostic Information 2-82
Diagnostic Information
2-82
4059-XXX
3
Stepper Motor Level 1
Check the stepper motor connector
to ensure it is correctly installed at J4
on the output expander option board.
Go to
“Output Expander Control
Board - Level 1 Stepper Motor” on
page 5-22
. If correct, disconnect J4
from the option board and check the
resistance of the stepper motor at
J4:
J4-1 to J4-2: Approximately 10 ohms
J4-3 to J4-4: Approximately 10
ohms.
Also check each winding for shorts
between J4-1 thru J4-4 and the
motor housing. If you find a problem,
replace the stepper motor. If you do
not find a problem, replace the
output expander mechanical linkage
assembly.
FRU
Action