Lexmark Optra S Service Manual - Page 67
Envelope Option, J1-5 measures +5 V dc
View all Lexmark Optra S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 67 highlights
4059-XXX FRU 3 Autoconnect on the Envelope Option Action Check the connector for any signs of damage to the connector or contacts. If you find damage, replace the damaged cable/connector assembly. Disconnect the autoconnect cable at J1 on the envelope system board and measure the following voltages: J1-3 measures +5 V dc J1-5 measures +5 V dc J1-7 measures +24 V dc If any of the voltages are incorrect, replace the autoconnect cable/connector. If the voltages are correct, replace the envelope system board. Diagnostic Information 2-40
Diagnostic Information
2-40
4059-XXX
3
Autoconnect on the
Envelope Option
Check the connector for any signs of
damage to the connector or
contacts. If you find damage, replace
the damaged cable/connector
assembly. Disconnect the
autoconnect cable at J1 on the
envelope system board and
measure the following voltages:
J1-3 measures +5 V dc
J1-5 measures +5 V dc
J1-7 measures +24 V dc
If any of the voltages are incorrect,
replace the autoconnect
cable/connector. If the voltages are
correct, replace the envelope system
board.
FRU
Action