PROGRAMMING Built in 3-channel, 315MHz radio receiver allows you to add as many as 23 Security✚® remotes or dip switch remote controls. PROGRAMMING REMOTES STANDARD SINGLE BUTTON REMOTE 1. To enter programming press and release the RADIO button on the logic board (LED will light). 2. Press and hold the remote button until the LED flashes rapidly, then release remote button. The LED will then remain on solid after releasing the button. Repeat to add additional remote(s). 3. Press and release the RADIO button to complete the programming. The programming mode is exited if no activity is performed within 30 seconds. NOTE: Single button remote is not supported with D1 and E2 failsafe wiring modes. NOTE: Requires self-monitoring photo eyes when using constant pressure to close (wiring C2, D1 and E2 ). SINGLE BUTTON CONTROL (SBC) REMOTE This function programs a remote as a wireless single button control. In B2 mode, operation is OPEN / STOP / CLOSE / REVERSE / STOP. In C2 mode, operation is OPEN / STOP/ Constant pressure to CLOSE / STOP on release. There is no operation in D1 mode. In T and TS modes, operation is OPEN / STOP / CLOSE / REVERSE / STOP and Timer to Close start/refresh. In FSTS mode, operation is OPEN with Timer to Close start/refresh only bypassing all up mid stops. Momentary and constant pressure commands are processed in this function. MODE B2 C2 D1 E2 T, TS FSTS OPEN      STOP     OPERATION CLOSE Reverse   Constant Timer To Pressure Close       1. Press and release the RADIO button on the logic board (LED will light). 2. Press and release the SBC externally wired button or TIMER on the logic board (LED flashes rapidly and then remains on solid). 3. Press and hold the remote button until the LED flashes rapidly. The LED will then remain on solid after releasing. 4. Press and release the RADIO button on the logic board (LED flashes rapidly and then turns off). The programming mode is exited if no activity is performed within 30 seconds. ERASING REMOTES Press and hold the RADIO button on the logic board until the RADIO LED flashes rapidly (approximately 5 seconds). All remotes will be erased. WARNING To prevent possible SERIOUS INJURY or DEATH, install CAUTION reversing sensors when the 3-button control station is out of sight of the door or ANY other control (automatic or manual) is used. Reversing devices are recommended for ALL installations. NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO LiftMaster P4 E1 R29 C11 D3Ø2 K3 Ø14LGØ65 X1 C54 U1 C71 C78 ® OLS D25 REV MID D24 SLS D26 D16 CLS D27 P7 MRT MID TIM RADIO 1 2 D36 RELAY C77 C73 L1 L5 RELAY D35 E2 D1 C2 B2 FAILSAFE P6 MOTOR 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

18
SINGLE BUTTON CONTROL (SBC) REMOTE
This function programs a remote as a wireless single button
control. In B2 mode, operation is OPEN / STOP / CLOSE /
REVERSE / STOP. In C2 mode, operation is OPEN / STOP/
Constant pressure to CLOSE / STOP on release. There is no
operation in D1 mode. In T and TS modes, operation is OPEN /
STOP / CLOSE / REVERSE / STOP and Timer to Close
start/refresh. In FSTS mode, operation is OPEN with Timer to
Close start/refresh only bypassing all up mid stops. Momentary
and constant pressure commands are processed in this function.
1. Press and release the RADIO button on the logic board (LED
will light).
2. Press and release the SBC externally wired button or TIMER on
the logic board (LED flashes rapidly and then remains on
solid).
3. Press and hold the remote button until the LED flashes rapidly.
The LED will then remain on solid after releasing.
4. Press and release the RADIO button on the logic board (LED
flashes rapidly and then turns off). The programming mode is
exited if no activity is performed within 30 seconds.
ERASING REMOTES
Press and hold the RADIO button on the logic board until the
RADIO LED flashes rapidly (approximately 5 seconds).
All remotes will be erased.
Built in 3-channel, 315MHz radio receiver allows you to add as
many as 23 Security
®
remotes or dip switch remote controls.
PROGRAMMING REMOTES
STANDARD SINGLE BUTTON REMOTE
1. To enter programming press and release the RADIO button on
the logic board (LED will light).
2. Press and hold the remote button until the LED flashes rapidly,
then release remote button. The LED will then remain on solid
after releasing the button. Repeat to add additional remote(s).
3. Press and release the RADIO button to complete the
programming. The programming mode is exited if no activity is
performed within 30 seconds.
NOTE:
Single button remote is not supported with D1 and E2
failsafe wiring modes.
NOTE:
Requires self-monitoring photo eyes when using constant
pressure to close (wiring C2, D1 and E2 ).
OPERATION
MODE
B2
C2
D1
E2
T, TS
FSTS
OPEN
STOP
CLOSE
Reverse
Constant
Pressure
Timer To
Close
PROGRAMMING
L
i
f
t
M
a
s
t
e
r
U1
MRT
1
RADIO
MID
2
TIM
E2
RELAY
RELAY
D1
C2
B2
OLS
MID
SLS
MOTOR
REV
±
CLS
D25
D24
D26
D27
D36
C77
C73
C54
C78
L1
L5
P6
D35
D16
P7
K3
FAILSAFE
X1
E1
R29
C11
D3
Ø
2
P4
Ø
14LG
Ø
65
C71
®
RADIO
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this
receiver and/or transmitter are prohibited, except for changing the code setting or replacing the
battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
To prevent possible SERIOUS INJURY or DEATH, install
reversing sensors when the 3-button control station is out of
sight of the door or ANY other control (automatic or manual) is
used. Reversing devices are recommended for ALL installations.
WARNING