CONTROL CONNECTION DIAGRAM IMPORTANT NOTES: 1. The 3-Button Control Station provided must be connected for operation. 2. If a STOP button is not used, a jumper must be placed between terminals 4 and 5. 3. When adding accessories, install them one at a time and test each one after it is added to ensure proper installation and operation with the Commercial Door Operator. 3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON STANDARD 2 OR MORE KEY LOCKOUT 10 7 6 4 5 10 7 6 4 5 10 7 6 4 5 (RED) Maintenance Alert LED (WHITE) Open Close Stop (RED) Maintenance Alert LED (WHITE) Open Close Stop Open Close Stop (RED) Maintenance Alert LED (WHITE) Open Close Stop Keyswitch 2 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER STANDARD 764 764 2 OR MORE Open D1 & E2 MODE ONLY Close See note 2. 1 BUTTON STATION OR ANY AUXILIARY DEVICE OPEN / CLOSE 14 B2, T, TS & FSTS MODE ONLY See note 2. Open Open D1 & E2 MODE ONLY Close Close RADIO CONTROLS OPEN / CLOSE R1 R2 R3 See note 2. Any Commercial Type LiftMaster Brand Receiver SENSING DEVICE TO REVERSE OR STOP Note: 11 and 4 are both the same common. Either is acceptable. 11 8 EXTERNAL INTERLOCK Remove Factory Installed Jumper When Interlock is Used 2 3 2 3 01-32851B Sensing Device ONE © 2006, The Chamberlain Group, Inc. All Rights Reserved 2 OR MORE All Wiring Types

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

CONTROL CONNECTION DIAGRAM
IMPORTANT NOTES:
1. The 3-Button Control Station provided must be connected for operation.
2. If a STOP button is not used, a jumper must be placed between terminals 4 and 5.
3. When adding accessories, install them one at a time and test each one after it is added to ensure proper installation and operation
with the Commercial Door Operator.
OPEN / CLOSE
3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON
2 OR MORE
KEY LOCKOUT
R1
R2
R3
7
6
4
5
Stop
Close
Open
Stop
Close
Open
7
6
4
5
Stop
Close
Open
2 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER
STANDARD
7
6
4
Close
Open
D1 & E2
MODE ONLY
2 OR MORE
7
6
4
Close
Open
Close
Open
D1 & E2
MODE ONLY
OPEN / CLOSE
1
4
B2, T, TS & FSTS
MODE ONLY
Any Commercial Type
LiftMaster Brand Receiver
1 BUTTON STATION OR ANY AUXILIARY DEVICE
RADIO CONTROLS
SENSING DEVICE TO REVERSE OR STOP
EXTERNAL INTERLOCK
11
8
2
3
2
3
Remove Factory Installed Jumper
When Interlock is Used
ONE
2 OR MORE
STANDARD
7
6
4
5
Stop
Close
Open
All Wiring Types
Keyswitch
Sensing Device
10
Maintenance
Alert LED
10
10
Maintenance
Alert LED
Maintenance
Alert LED
(RED)
(WHITE)
(RED)
(WHITE)
(RED)
(WHITE)
Note: 11 and 4 are both the same common.
Either is acceptable.
See note 2.
See note 2.
See note 2.
© 2006, The Chamberlain Group, Inc.
01-32851B
All Rights Reserved