Scanner Emulation Interface 11 - 7 Convert Newer Code Types The digital scanner supports a variety of code types that are not decodable by attached decoder systems. To allow compatibility in these environments, the digital scanner converts these code types to more commonly decodable symbologies, as per the following chart. Symbologies not listed on this chart transmit normally. Scan this Code Type: Code 11 GS1 DataBar (14, Limited, and Expanded), Coupon Code, PDF, MicroPDF, MaxiCode, Data Matrix, QR Code, Postal Codes, Composite Codes Transmitted as: Code 39 Code 128 When decoding these code types with this parameter disabled, the digital scanner issues Convert Error beeps and transmits no data. The amount of data in the scanned newer bar code type should not exceed that of the conversion code type. *Convert Newer Code Types Reject Newer Code Types Module Width The standard module width is 20 µs. For an extremely slow decoder system, select 50 µs Module Width. *20 µs Module Width 50 µs Module Width