Check ISBT Table, ISBT Concatenation Redundancy, ISBT Concatenation, Enable, Autodiscriminate
View all Motorola DS6708-DL20291ZZR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 203 highlights
Symbologies 13 - 27 Check ISBT Table Parameter # F1h 42h The ISBT specification includes a table that lists several types of ISBT bar codes that are commonly used in pairs. If you set ISBT Concatenation to Enable, enable Check ISBT Table to concatenate only those pairs found in this table. Other types of ISBT codes are not concatenated. *Enable Check ISBT Table (01h) Disable Check ISBT Table (00h) ISBT Concatenation Redundancy Parameter # DFh If you set ISBT Concatenation to Autodiscriminate, use this parameter to set the number of times the digital scanner must decode an ISBT symbol before determining that there is no additional symbol. Scan the bar code below, then scan two numeric bar codes in Appendix D, Numeric Bar Codes to set a value between 2 and 20. Enter a leading zero for single digit numbers. To correct an error or change a selection, scan Cancel on page D-2. The default is 10. ISBT Concatenation Redundancy