Samsung DV435GTGJRA/A1 User Manual Ver.1.0 (English, French, Spanish) - Page 13

Location Considerations, Alcove Or Closet Installations

Page 13 highlights

01 INSTALLING YOUR DRYER LOCATION CONSIDERATIONS The dryer should be located where there is enough space at the front for loading the dryer, and enough space behind for the exhaust system. This dryer is factory-ready for the rear exhaust option. To exhaust out the bottom, right or the left, use the accessory exhaust kit. Instructions are included with the kit. Make sure the room in which the dryer is located has enough fresh air. The dryer must be located where there are no air-flow obstructions. For gas dryers, adequate clearance must be maintained as noted on the data plate to ensure adequate air for combustion and the proper dryer operation. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. The dryer area must be kept clear of combustible materials, gasoline, and other flammable vapors and liquids. A dryer produces combustible lint. The area around the dryer should be kept lint-free. ALCOVE OR CLOSET INSTALLATIONS The dryer must be exhausted to the outside to reduce the risk of fire when installed in an alcove or WARNING closet. • No other fuel-burning appliance should be installed in the same closet as the dryer. • WARNING: To reduce the risk of fire, this dryer must be exhausted to the outside. Refer to the "Exhausting" section on page 15. Minimum clearances between the dryer and adjacent walls or other surfaces Sides Top 1 in / 25 mm 17 in / 432 mm Rear Front 5 in / 127 mm 2 in / 51 mm • The front of the closet must have two unobstructed air openings for a combined minimum total area of 72 in² (465 cm²) with a minimum clearance of 3" (7.6 cm) at the top and bottom. A slatted door with equivalent space clearances is acceptable. Recessed area Side view - closet or confined area 1 in. (2.5 cm) 17 in. (43.2 cm) 1 in. (2.5 cm) 27 in. (68.6 cm) 27 in. (68.6 cm) 1 in. (2.5 cm) 2 in. (5 cm) 34.1 in. (86.5 cm) 5 in. (12.7 cm) DV435-02836G_EN_20120522.indd 13 Installing your dryer _13 2012-05-22 12:13:45

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144

Installing your dryer _
13
01 INSTALLING YOUR DRYER
LOCATION CONSIDERATIONS
The dryer should be located where there is enough space at the front for loading the dryer, and enough
space behind for the exhaust system. This dryer is factory-ready for the rear exhaust option. To exhaust out
the bottom, right or the left, use the accessory exhaust kit. Instructions are included with the kit. Make sure
the room in which the dryer is located has enough fresh air. The dryer must be located where there are no
air-flow obstructions.
For gas dryers, adequate clearance must be maintained as noted on the data plate to ensure adequate air
for combustion and the proper dryer operation.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. The
dryer area must be kept clear of combustible materials, gasoline, and other flammable vapors and liquids. A
dryer produces combustible lint. The area around the dryer should be kept lint-free.
ALCOVE OR CLOSET INSTALLATIONS
The dryer must be exhausted to the outside to reduce the risk of fire when installed in an alcove or
closet.
No other fuel-burning appliance should be installed in the same closet as the dryer.
WARNING: To reduce the risk of fire, this dryer must be exhausted to the outside. Refer to the
Exhausting
” section on page 15.
Minimum clearances between the dryer and adjacent walls or other
surfaces
Sides
1 in / 25 mm
Rear
5 in / 127 mm
Top
17 in / 432 mm
Front
2 in / 51 mm
The front of the closet must have two unobstructed air openings for a combined minimum
total area of 72 in² (465 cm²) with a minimum clearance of 3” (7.6 cm) at the top and bottom.
A slatted door with equivalent space clearances is acceptable.
Recessed area
Side view - closet or confined area
1 in.
(2.5 cm)
1 in.
(2.5 cm)
1 in.
(2.5 cm)
27 in.
(68.6 cm)
27 in.
(68.6 cm)
2 in.
(5 cm)
5 in.
(12.7 cm)
34.1 in.
(86.5 cm)
17 in.
(43.2 cm)
WARNING
DV435-02836G_EN_20120522.indd 13
DV435-02836G_EN_20120522.indd
13
2012-05-22
12:13:45
2012-05-22
12:13:45