CARING FOR YOUR MACHINE (Continued) This machine is designed to use a 15 watt maximum light bulb. Locks Unlocks This machine is designed to use a 15 watt maximum light bulb Bulb Pin Changing the Light Bulb CHANGING THE LIGHT BULB Disconnect power-line plug from electrical supply. Removing the Bulb With thumb and forefinger lower the light bracket. Do not attempt to unscrew bulb. Press it up into socket and at same time turn bulb over in direction shown to unlock bulb pin. Replacing the Bulb Press new bulb into socket with bulb pin entering slot of socket, and turn it over in direction shown to lock bulb in position. Release bracket, and entire assembly will snap back into recess. Raise Presser Foot and Needle Lift Retaining Spring into Slide Plate Grooves Replacing the Slide Plate 46 REPLACING THE SLIDE PLATE You will not have any occasion to remove the slide plate. However, if it should accidentally become disengaged from the machine, it is easily replaced. . Raise presser foot and needle. . Place slide plate in slideway with the front edge close to, but not covering, the retaining spring (as shown in illustration). • With a screwdriver, lift each end of the spring into each of the side grooves on the underside of the slide plate. . Draw the plate gently toward you and fully engage the spring. . Close slide plate.