Sony CX150 Operating Instructions - Page 60

VPL-CW125, The alphabetical letters in the charts and calculation methods indicate the following.

Page 60 highlights

VPL-CX100/CX120/CX125/CX150/CX155 (When an XGA signal is input) Unit: mm (inches) PS 40 60 80 100 120 150 180 200 250 300 a N 1170 1770 2380 2990 3590 4500 5410 6020 7540 (46 1/8) (69 3/4) (93 3/4) (117 3/4) (141 3/8) (177 1/4) (213 1/8) (237 1/16) (297) 9050 (356 3/8) M 1350 2050 2750 3450 4140 5190 6240 6940 8680 10430 (53 1/4) (80 3/4) (108 3/8) (135 7/8) (163 1/8) (204 3/8) (245 3/4) (273 3/8) (341 7/8) (410 3/4) b x-237 x-356 x-474 x-593 x-711 x-889 x-1067 x-1185 x-1482 x-1778 (x-9 3/8) (x-14) (x-18 3/4) (x-23 3/8) (x-28) (x-35) (x-42) (x-46 3/4) (x-58 3/8) (x-70 1/8) c x-298 x-417 x-535 x-654 x-772 x-950 x-1128 x-1247 x-1543 x-1839 (x-11 3/4) (x-16 1/2) (x-21 1/8) (x-25 3/4) (x-30 1/2) (x-37 1/2) (x-44 1/2) (x-49 1/8) (x-60 3/4) (x-72 1/2) a (N) = {(PS × 23.306/0.7874)-46.6} × 1.025 a (M) = {(PS × 28.188/0.7874)-45.9} × 0.975 b = x-(PS/0.7874 × 4.667) c = x-(PS/0.7874 × 4.667+61.2) VPL-CW125 (When "Aspect" on the Signal menu is set to "Full 2") Unit: mm (inches) PS 40 60 80 100 120 150 180 200 250 300 a N 1260 1920 2570 3230 3880 4870 5850 6500 (49 5/8) (75 5/8) (101 1/4) (127 1/4) (152 7/8) (191 7/8) (230 3/8) (256) 8140 9780 (320 5/8) (385 1/8) M 1460 2220 2970 (57 1/2) (87 1/2) (117) 3720 4480 5610 (146 1/2) (176 1/2) (211) 6740 7490 (265 1/2) (295) 9370 (369) 11260 (443 3/8) b x-257 x-385 x-513 x-642 x-770 x-963 x-1155 x-1284 x-1605 x-1925 (x-10 1/8) (x-15 1/4) (x-20 1/4) (x-25 3/8) (x-30 3/8) (x-38 29/32) (x-45 1/2) (x-50 5/8) (x-63 3/16) (x-75 7/8) c x-318 x-446 x-575 x-703 x-831 x-1024 x-1216 x-1345 x-1666 x-1987 (x-12 5/8) (x-17 5/8) (x-22 5/8) (x-27 3/4) (x-32 3/4) (x-40 3/8) (x-47 7/8) (x-53) (x-65 5/8) (x-78 1/4) a (N) = {(PS × 23.3/0.7292)-46.6} × 1.025 a (M) = {(PS × 28.171/0.7292)-45.650} × 0.975 b = x-(PS/0.7292 × 4.68) c = x-(PS/0.7292 × 4.68+61.2) Notes for VPL-CW125 only • The projected image size is the one when "Aspect" on the Signal menu is set to "Full 2". When "Aspect" on the Signal menu is set to other than "Full 2", black bands appear at the top and bottom or right and left of the screen. • When "Aspect" in the Signal menu is set to "4:3", the projected image size (diagonal) will be approximately 84 % of "Full 2" size. • When "Aspect" in the Signal menu is set to "16:9", the projected image size (diagonal) will be approximately 99 % of "Full 2" size. The alphabetical letters in the charts and calculation methods indicate the following. PS: projected image size measured diagonally (inches) a: distance between the screen and the center of the lens b: distance between the floor and the center of the lens c: distance between the floor and the adjusters of the projector x: free N: minimum M: maximum 60 Installation Diagram

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

60
Installation Diagram
VPL-CX100/CX120/CX125/CX150/CX155
(When an XGA signal is input)
a (N) = {(PS × 23.306/0.7874)–46.6} × 1.025
a (M) = {(PS × 28.188/0.7874)–45.9} × 0.975
b = x–(PS/0.7874 × 4.667)
c = x–(PS/0.7874 × 4.667+61.2)
VPL-CW125
(When “Aspect” on the Signal menu is set to “Full 2”)
a (N) = {(PS × 23.3/0.7292)–46.6} × 1.025
a (M) = {(PS × 28.171/0.7292)–45.650} × 0.975
b = x–(PS/0.7292 × 4.68)
c = x–(PS/0.7292 × 4.68+61.2)
The projected image size is the one when “Aspect” on the Signal menu is set to “Full 2”. When
“Aspect” on the Signal menu is set to other than “Full 2”, black bands appear at the top and bottom
or right and left of the screen.
When “Aspect” in the Signal menu is set to “4:3”, the projected image size (diagonal) will be
approximately 84 % of “Full 2” size.
When “Aspect” in the Signal menu is set to “16:9”, the projected image size (diagonal) will be
approximately 99 % of “Full 2” size.
The alphabetical letters in the charts and calculation methods indicate the following.
PS:
projected image size measured diagonally (inches)
a:
distance between the screen and the center of the lens
b:
distance between the floor and the center of the lens
c:
distance between the floor and the adjusters of the projector
x:
free
N:
minimum
M:
maximum
Unit: mm (inches)
PS
40
60
80
100
120
150
180
200
250
300
a
N
1170
(46
1
/
8
)
1770
(69
3
/
4
)
2380
(93
3
/
4
)
2990
(117
3
/
4
)
3590
(141
3
/
8
)
4500
(177
1
/
4
)
5410
(213
1
/
8
)
6020
(237
1
/
16
)
7540
(297)
9050
(356
3
/
8
)
M
1350
(53
1
/
4
)
2050
(80
3
/
4
)
2750
(108
3
/
8
)
3450
(135
7
/
8
)
4140
(163
1
/
8
)
5190
(204
3
/
8
)
6240
(245
3
/
4
)
6940
(273
3
/
8
)
8680
(341
7
/
8
)
10430
(410
3
/
4
)
b
x-237
(x-9
3
/
8
)
x-356
(x-14)
x-474
(x-18
3
/
4
)
x-593
(x-23
3
/
8
)
x-711
(x-28)
x-889
(x-35)
x-1067
(x-42)
x-1185
(x-46
3
/
4
)
x-1482
(x-58
3
/
8
)
x-1778
(x-70
1
/
8
)
c
x-298
(x-11
3
/
4
)
x-417
(x-16
1
/
2
)
x-535
(x-21
1
/
8
)
x-654
(x-25
3
/
4
)
x-772
(x-30
1
/
2
)
x-950
(x-37
1
/
2
)
x-1128
(x-44
1
/
2
)
x-1247
(x-49
1
/
8
)
x-1543
(x-60
3
/
4
)
x-1839
(x-72
1
/
2
)
Unit: mm (inches)
PS
40
60
80
100
120
150
180
200
250
300
a
N
1260
(49
5
/
8
)
1920
(75
5
/
8
)
2570
(
101
1
/
4
)
3230
(127
1
/
4
)
3880
(152
7
/
8
)
4870
(191
7
/
8
)
5850
(230
3
/
8
)
6500
(256)
8140
(320
5
/
8
)
9780
(385
1
/
8
)
M
1460
(57
1
/
2
)
2220
(87
1
/
2
)
2970
(117)
3720
(146
1
/
2
)
4480
(176
1
/
2
)
5610
(211)
6740
(265
1
/
2
)
7490
(295)
9370
(369)
11260
(443
3
/
8
)
b
x-257
(
x-10
1
/
8
)
x-385
(x-15
1
/
4
)
x-513
(x-20
1
/
4
)
x-642
(x-25
3
/
8
)
x-770
(x-30
3
/
8
)
x-963
(
x-38
29
/
32
)
x-1155
(x-45
1
/
2
)
x-1284
(x-50
5
/
8
)
x-1605
(
x-63
3
/
16
)
x-1925
(x-75
7
/
8
)
c
x-318
(x-12
5
/
8
)
x-446
(x-17
5
/
8
)
x-575
(x-22
5
/
8
)
x-703
(x-27
3
/
4
)
x-831
(x-32
3
/
4
)
x-1024
(x-40
3
/
8
)
x-1216
(x-47
7
/
8
)
x-1345
(x-53)
x-1666
(x-65
5
/
8
)
x-1987
(x-78
1
/
4
)
Notes for VPL-CW125 only